Effect of External Linear Model?s order on Adaptive Control of CSTR
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28140%2F11%3A43866518" target="_blank" >RIV/70883521:28140/11:43866518 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/70883521:28610/11:43866518
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effect of External Linear Model?s order on Adaptive Control of CSTR
Popis výsledku v původním jazyce
This paper shows simulation results of the adaptive control with different types of External Linear Models (ELM) used in adaptive control as a representation of the nonlinear system. The controlled nonlinear system was Continuous Stirred Tank Reactor (CSTR) with exothermic reaction and cooling in the jacket. The mathematical model of this plant is described by the set of ordinary differential equations (ODE) which means that the system is considered as a lumped-parameters system. Adaptive approach withthe recursive identification of the ELM?s parameters used here produces good control results even when the system has negative control properties. The polynomial synthesis and the pole-placement method applied for the controller design satisfies basic control requirements such as stability, reference tracking and disturbance attenuation which was also proofed.
Název v anglickém jazyce
Effect of External Linear Model?s order on Adaptive Control of CSTR
Popis výsledku anglicky
This paper shows simulation results of the adaptive control with different types of External Linear Models (ELM) used in adaptive control as a representation of the nonlinear system. The controlled nonlinear system was Continuous Stirred Tank Reactor (CSTR) with exothermic reaction and cooling in the jacket. The mathematical model of this plant is described by the set of ordinary differential equations (ODE) which means that the system is considered as a lumped-parameters system. Adaptive approach withthe recursive identification of the ELM?s parameters used here produces good control results even when the system has negative control properties. The polynomial synthesis and the pole-placement method applied for the controller design satisfies basic control requirements such as stability, reference tracking and disturbance attenuation which was also proofed.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BC - Teorie a systémy řízení
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 19th IASTED International Conference on Applied Simulation and Modelling
ISBN
978-0-88986-884-7
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
82-87
Název nakladatele
ACTA Press
Místo vydání
Calgary
Místo konání akce
Kréta
Datum konání akce
22. 6. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—