Saturation relay vs. relay transient identification tests for a TDS model
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28140%2F13%3A43870351" target="_blank" >RIV/70883521:28140/13:43870351 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.7148/2013-0446" target="_blank" >http://dx.doi.org/10.7148/2013-0446</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.7148/2013-0446" target="_blank" >10.7148/2013-0446</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Saturation relay vs. relay transient identification tests for a TDS model
Popis výsledku v původním jazyce
The paper brings a comparison of two novel combinations of a relay identification test with a Time Delay System (TDS) model. Namely, the on/off plus saturation relay test and relay transient experiment are introduced. In the former case with more then two unknown model parameters, it is necessary to apply some technique for frequency response multiple-points identification; here, the Autotune Variation Plus (ATV+) procedure introducing an artificial delay is utilized. Limit cycles data are evaluated viaan unordinary time-domain approach and using the Discrete Time Fourier Transform (DTFT), respectively. Both methodologies are verified and compared on a model of the circuit heating laboratory system with internal delays.
Název v anglickém jazyce
Saturation relay vs. relay transient identification tests for a TDS model
Popis výsledku anglicky
The paper brings a comparison of two novel combinations of a relay identification test with a Time Delay System (TDS) model. Namely, the on/off plus saturation relay test and relay transient experiment are introduced. In the former case with more then two unknown model parameters, it is necessary to apply some technique for frequency response multiple-points identification; here, the Autotune Variation Plus (ATV+) procedure introducing an artificial delay is utilized. Limit cycles data are evaluated viaan unordinary time-domain approach and using the Discrete Time Fourier Transform (DTFT), respectively. Both methodologies are verified and compared on a model of the circuit heating laboratory system with internal delays.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BC - Teorie a systémy řízení
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0089" target="_blank" >ED2.1.00/03.0089: Centrum bezpečnostních, informačních a pokročilých technologií (CEBIA-Tech)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
27th European Conference on Modelling and Simulation
ISBN
978-0-9564944-6-7
ISSN
—
e-ISSN
—
Počet stran výsledku
7
Strana od-do
446-452
Název nakladatele
ECMS
Místo vydání
Alesund
Místo konání akce
Alesund
Datum konání akce
27. 5. 2013
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—