Improved LTI TDS model identification using a saturation relay: An application example
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28140%2F13%3A43870352" target="_blank" >RIV/70883521:28140/13:43870352 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Improved LTI TDS model identification using a saturation relay: An application example
Popis výsledku v původním jazyce
The paper attacks the relay-feedback based identification of Linear Time-Invariant Time Delay Systems (LTI TDS) as a part of the autotuning process. Instead of the sole use of the conventional on/off relay, its combination with a saturation relay is presented, which brings more accurate model parameters estimation. In the case of more then two unknown model parameters, it is necessary to apply some technique for frequency response multiple-points identification; here, the Autotune Variation Plus (ATV+)procedure introducing an additional artificial delay is utilized. Limit cycles data are then evaluated via an uncommon time-domain approach supported by numerical solutions via several iterative algorithms. The methodology is, eventually, verified on theparameters' estimation of a laboratory circuit heating LTI TDS model, both, by simulations and real measurements
Název v anglickém jazyce
Improved LTI TDS model identification using a saturation relay: An application example
Popis výsledku anglicky
The paper attacks the relay-feedback based identification of Linear Time-Invariant Time Delay Systems (LTI TDS) as a part of the autotuning process. Instead of the sole use of the conventional on/off relay, its combination with a saturation relay is presented, which brings more accurate model parameters estimation. In the case of more then two unknown model parameters, it is necessary to apply some technique for frequency response multiple-points identification; here, the Autotune Variation Plus (ATV+)procedure introducing an additional artificial delay is utilized. Limit cycles data are then evaluated via an uncommon time-domain approach supported by numerical solutions via several iterative algorithms. The methodology is, eventually, verified on theparameters' estimation of a laboratory circuit heating LTI TDS model, both, by simulations and real measurements
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BC - Teorie a systémy řízení
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0089" target="_blank" >ED2.1.00/03.0089: Centrum bezpečnostních, informačních a pokročilých technologií (CEBIA-Tech)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 14th WSEAS International Conference on Automation & Information (ICAI ?13)
ISBN
978-960-474-316-2
ISSN
1790-5117
e-ISSN
—
Počet stran výsledku
6
Strana od-do
75-80
Název nakladatele
WSEAS Press
Místo vydání
Montreux
Místo konání akce
Valencie
Datum konání akce
6. 8. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—