Comparison of Two Identification Models Used in Adaptive Control of Continuous-Stirred Tank Reactor
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28140%2F16%3A43875460" target="_blank" >RIV/70883521:28140/16:43875460 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1051/matecconf/20167601005" target="_blank" >http://dx.doi.org/10.1051/matecconf/20167601005</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1051/matecconf/20167601005" target="_blank" >10.1051/matecconf/20167601005</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of Two Identification Models Used in Adaptive Control of Continuous-Stirred Tank Reactor
Popis výsledku v původním jazyce
The goal of this paper is to compare two identification methods - continuous-time and discrete-time. The continuous-time identification model is more accurate but not very suitable for on-line identification. This disadvantage was overcome with the use of differential filters. On the other hand, discrete-time identification model has is more suitable for identification but less accurate. Compromise can be found in the delta model as a special type of the discrete-time model parameters of which are related to the sampling period. The adaptive approach is based on the choice of the External Linear Model, parameters of which are identified recursively which satisfies the adaptivity of this system. Proposed control strategy was applied on the mathematical model of the Continuous Stirred-Tank reactor as a typical nonlinear lumped-parameters system used in the industry.
Název v anglickém jazyce
Comparison of Two Identification Models Used in Adaptive Control of Continuous-Stirred Tank Reactor
Popis výsledku anglicky
The goal of this paper is to compare two identification methods - continuous-time and discrete-time. The continuous-time identification model is more accurate but not very suitable for on-line identification. This disadvantage was overcome with the use of differential filters. On the other hand, discrete-time identification model has is more suitable for identification but less accurate. Compromise can be found in the delta model as a special type of the discrete-time model parameters of which are related to the sampling period. The adaptive approach is based on the choice of the External Linear Model, parameters of which are identified recursively which satisfies the adaptivity of this system. Proposed control strategy was applied on the mathematical model of the Continuous Stirred-Tank reactor as a typical nonlinear lumped-parameters system used in the industry.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BC - Teorie a systémy řízení
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
MATEC Web of Conferences
ISBN
—
ISSN
2261-236X
e-ISSN
—
Počet stran výsledku
6
Strana od-do
"nestrankovano"
Název nakladatele
EDP Sciences
Místo vydání
Les Ulis
Místo konání akce
Corfu Island
Datum konání akce
14. 7. 2016
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000392332200005