An Analysis of Curing of Epoxy Resin by Steady-State Fluorescence Spectroscopy and Determination of a Storage Temperature
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28140%2F18%3A63519889" target="_blank" >RIV/70883521:28140/18:63519889 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.daaam.info/Downloads/Pdfs/proceedings/proceedings_2018/162.pdf" target="_blank" >http://www.daaam.info/Downloads/Pdfs/proceedings/proceedings_2018/162.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2507/29th.daaam.proceedings.162" target="_blank" >10.2507/29th.daaam.proceedings.162</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
An Analysis of Curing of Epoxy Resin by Steady-State Fluorescence Spectroscopy and Determination of a Storage Temperature
Popis výsledku v původním jazyce
Steady-state fluorescence spectroscopy is used to analyse the curing of epoxy resin. The analysed mixture of epoxy resin EPOXY 1200 and hardener P11 is measured at seven different temperatures: at room temperature (23 °C), at the lower temperature (9 °C) and at the higher temperatures (30 °C, 40 °C, 50 °C, 70 °C and 80 °C). The results demonstrate that the process of curing of epoxy resin accelerates with increasing temperature. The measured data are further processed to determine a storage temperature. The appropriate storage temperature for the analysed mixture is stated as 4 °C or less.
Název v anglickém jazyce
An Analysis of Curing of Epoxy Resin by Steady-State Fluorescence Spectroscopy and Determination of a Storage Temperature
Popis výsledku anglicky
Steady-state fluorescence spectroscopy is used to analyse the curing of epoxy resin. The analysed mixture of epoxy resin EPOXY 1200 and hardener P11 is measured at seven different temperatures: at room temperature (23 °C), at the lower temperature (9 °C) and at the higher temperatures (30 °C, 40 °C, 50 °C, 70 °C and 80 °C). The results demonstrate that the process of curing of epoxy resin accelerates with increasing temperature. The measured data are further processed to determine a storage temperature. The appropriate storage temperature for the analysed mixture is stated as 4 °C or less.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10201 - Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8)
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 29th DAAAM International Symposium
ISBN
978-3-902734-20-4
ISSN
1726-9679
e-ISSN
neuvedeno
Počet stran výsledku
4
Strana od-do
1135-1138
Název nakladatele
DAAAM International Vienna
Místo vydání
Vienna
Místo konání akce
Zadar
Datum konání akce
24. 10. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—