Can a wearable strain sensor based on a carbon nanotube network be an alternative to an isokinetic dynamometer for the measurement of knee-extensor muscle strength?
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28610%2F17%3A63517175" target="_blank" >RIV/70883521:28610/17:63517175 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1088/1361-6501/aa5cfa" target="_blank" >http://dx.doi.org/10.1088/1361-6501/aa5cfa</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1361-6501/aa5cfa" target="_blank" >10.1088/1361-6501/aa5cfa</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Can a wearable strain sensor based on a carbon nanotube network be an alternative to an isokinetic dynamometer for the measurement of knee-extensor muscle strength?
Popis výsledku v původním jazyce
This study aimed to find out whether a wearable strain sensor including thermoplastic polyurethane composite with a multi-walled carbon nanotube network could be a viable alternative to an isokinetic dynamometer for the measurement of knee-extensor muscle strength. For the first time, the voltage-torque and angle-time relations of the sensor were determined to allow a comparison between the angle-dependent torque changes of the dynamometer and the sensor. This comparison suggested that the torque-angle relations of the dynamometer and the sensor did not have the same characteristics. In this regard, the sensor may be used in the torque measurements due to the moderate correlation between the torque values determined via the isokinetic dynamometer and the sensor and due to the significant difference between low and high torque values of the sensor. By the same token, the torque-angle graph of the sensor may be more informative than that of the dynamometer in evaluation of knee problems.
Název v anglickém jazyce
Can a wearable strain sensor based on a carbon nanotube network be an alternative to an isokinetic dynamometer for the measurement of knee-extensor muscle strength?
Popis výsledku anglicky
This study aimed to find out whether a wearable strain sensor including thermoplastic polyurethane composite with a multi-walled carbon nanotube network could be a viable alternative to an isokinetic dynamometer for the measurement of knee-extensor muscle strength. For the first time, the voltage-torque and angle-time relations of the sensor were determined to allow a comparison between the angle-dependent torque changes of the dynamometer and the sensor. This comparison suggested that the torque-angle relations of the dynamometer and the sensor did not have the same characteristics. In this regard, the sensor may be used in the torque measurements due to the moderate correlation between the torque values determined via the isokinetic dynamometer and the sensor and due to the significant difference between low and high torque values of the sensor. By the same token, the torque-angle graph of the sensor may be more informative than that of the dynamometer in evaluation of knee problems.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Measurement Science and Technology
ISSN
0957-0233
e-ISSN
—
Svazek periodika
28
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
10
Strana od-do
1-10
Kód UT WoS článku
000395892800001
EID výsledku v databázi Scopus
2-s2.0-85014487964