Ultrasound irradiation to visualize and trigger the release of doxorubicin from hybrid microparticles
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28610%2F18%3A63521496" target="_blank" >RIV/70883521:28610/18:63521496 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Ultrasound irradiation to visualize and trigger the release of doxorubicin from hybrid microparticles
Popis výsledku v původním jazyce
In the presented work the simultaneous use of ultrasound in tracking and smart release was investigated. Hybrid microparticles based on an iron core coated by a polysaccharide were prepared and loaded with doxorubicin. The possibility to trigger and control the release of the payload was demonstrated by application of ultrasound cycles at different power and time length. Results clearly indicate a direct correlation between the intensity of the release with the two parameters. A preliminary test using Sus Domestic liver demonstrates the possibility to visualize the faith of the microparticles after injection at the target site by a linear array ultrasound transducer. The dual function of the ultrasound; to visualize the position of the microparticles and afterwards trigger the release by changing the frequency was demonstrated offering a great perspective for a future biomedical application.
Název v anglickém jazyce
Ultrasound irradiation to visualize and trigger the release of doxorubicin from hybrid microparticles
Popis výsledku anglicky
In the presented work the simultaneous use of ultrasound in tracking and smart release was investigated. Hybrid microparticles based on an iron core coated by a polysaccharide were prepared and loaded with doxorubicin. The possibility to trigger and control the release of the payload was demonstrated by application of ultrasound cycles at different power and time length. Results clearly indicate a direct correlation between the intensity of the release with the two parameters. A preliminary test using Sus Domestic liver demonstrates the possibility to visualize the faith of the microparticles after injection at the target site by a linear array ultrasound transducer. The dual function of the ultrasound; to visualize the position of the microparticles and afterwards trigger the release by changing the frequency was demonstrated offering a great perspective for a future biomedical application.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
30404 - Biomaterials (as related to medical implants, devices, sensors)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
NANOCON 2017 Conference Proceedings
ISBN
978-80-87294-81-9
ISSN
—
e-ISSN
neuvedeno
Počet stran výsledku
4
Strana od-do
485-488
Název nakladatele
Tanger Ltd.
Místo vydání
Ostrava
Místo konání akce
Brno
Datum konání akce
18. 10. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000452823300079