A rapid and sensitive HPLC method for simultaneous determination of irinotecan hydrochloride and curcumin in co-delivered polymeric nanoparticles
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28610%2F20%3A63526448" target="_blank" >RIV/70883521:28610/20:63526448 - isvavai.cz</a>
Výsledek na webu
<a href="https://academic.oup.com/chromsci/article-abstract/58/7/651/5867553" target="_blank" >https://academic.oup.com/chromsci/article-abstract/58/7/651/5867553</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/chromsci/bmaa033" target="_blank" >10.1093/chromsci/bmaa033</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A rapid and sensitive HPLC method for simultaneous determination of irinotecan hydrochloride and curcumin in co-delivered polymeric nanoparticles
Popis výsledku v původním jazyce
In recent years, a great deal of attention has been paid to the combined use of multiple antitumor drugs for better cancer treatment. The aims of the study are to construct a nanoparticle drug delivery system for the co-delivery of irinotecan hydrochloride and curcumin and to develop an analytical method for simultaneously quantifying these molecules, which is essential for further studies of the co-delivered nano system. The irinotecan hydrochloride and curcumin co-delivered nanoparticle (ICN) were prepared by combinatorially entrapping them into polyethylene glycol-poly lactic acid-co-glycolic acid (PEG-PLGA) polymeric nanoparticles. A simple, sensitive and rapid high-performance liquid chromatography method was developed and validated to simultaneously quantify the compounds in the co-delivered nanoparticle system. Acetonitrile and ultrapure water containing sodium dodecyl sulfate (0.08 mol/L), disodium phosphate (Na2HPO4, 0.002 mol/L) and acetic acid (4%, v/v) were used as the mobile phase and their ratio was set at 50:50. The flow rate was set to 1.0 mL/min, and the temperature in the column oven was maintained at 40°C. The analysis was carried out at 256 and 424 nm to assess irinotecan hydrochloride and curcumin, respectively. Detectors with only one channel can also visualize both analytes in one chromatogram at 379 nm and still demonstrate acceptable sensitivity. The retention times for irinotecan hydrochloride and curium were 3.317 and 5.560 min, respectively. The method developed was confirmed to be sensitive, accurate (recovery, 100 ± 2%), precise (relative standard deviation, RSD ≤ 1%), robust and linear (R2 ≥ 0.9996) in the range from 2.05 to 1050 μg/mL. The presented method has been used to quantify irinotecan hydrochloride and curcumin in the co-delivered ICN nano system to assess the drug delivery quality of the nanoparticles and can also be used for routine analysis because of its simplicity and accuracy. © The Author(s) 2020. Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.
Název v anglickém jazyce
A rapid and sensitive HPLC method for simultaneous determination of irinotecan hydrochloride and curcumin in co-delivered polymeric nanoparticles
Popis výsledku anglicky
In recent years, a great deal of attention has been paid to the combined use of multiple antitumor drugs for better cancer treatment. The aims of the study are to construct a nanoparticle drug delivery system for the co-delivery of irinotecan hydrochloride and curcumin and to develop an analytical method for simultaneously quantifying these molecules, which is essential for further studies of the co-delivered nano system. The irinotecan hydrochloride and curcumin co-delivered nanoparticle (ICN) were prepared by combinatorially entrapping them into polyethylene glycol-poly lactic acid-co-glycolic acid (PEG-PLGA) polymeric nanoparticles. A simple, sensitive and rapid high-performance liquid chromatography method was developed and validated to simultaneously quantify the compounds in the co-delivered nanoparticle system. Acetonitrile and ultrapure water containing sodium dodecyl sulfate (0.08 mol/L), disodium phosphate (Na2HPO4, 0.002 mol/L) and acetic acid (4%, v/v) were used as the mobile phase and their ratio was set at 50:50. The flow rate was set to 1.0 mL/min, and the temperature in the column oven was maintained at 40°C. The analysis was carried out at 256 and 424 nm to assess irinotecan hydrochloride and curcumin, respectively. Detectors with only one channel can also visualize both analytes in one chromatogram at 379 nm and still demonstrate acceptable sensitivity. The retention times for irinotecan hydrochloride and curium were 3.317 and 5.560 min, respectively. The method developed was confirmed to be sensitive, accurate (recovery, 100 ± 2%), precise (relative standard deviation, RSD ≤ 1%), robust and linear (R2 ≥ 0.9996) in the range from 2.05 to 1050 μg/mL. The presented method has been used to quantify irinotecan hydrochloride and curcumin in the co-delivered ICN nano system to assess the drug delivery quality of the nanoparticles and can also be used for routine analysis because of its simplicity and accuracy. © The Author(s) 2020. Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10404 - Polymer science
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1504" target="_blank" >LO1504: Centrum polymerních systémů plus</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of chromatographic science
ISSN
1945-239X
e-ISSN
—
Svazek periodika
58
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
651-660
Kód UT WoS článku
000582307300009
EID výsledku v databázi Scopus
2-s2.0-85088681703