On the replacement of articular cartilage: The friction of PVA hydrogel layer in hip simulator test
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28610%2F23%3A63564578" target="_blank" >RIV/70883521:28610/23:63564578 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26210/23:PU146248
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0301679X22006715?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0301679X22006715?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.triboint.2022.108100" target="_blank" >10.1016/j.triboint.2022.108100</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
On the replacement of articular cartilage: The friction of PVA hydrogel layer in hip simulator test
Popis výsledku v původním jazyce
The present study focuses on friction evaluation of the polyvinyl alcohol (PVA) hydrogel layer, an anticipative material for cartilage replacement. The experiments were carried out in a ball-in-socket configuration using a pendulum hip simulator. The friction coefficients of ceramic-on-hydrogel pairs were compared with those of commercial implants (metal/ceramic heads vs UHMWPE, HXPE and metal/ceramic sockets). The effects of hydrogel ageing and hydration were studied, among others. The use of PVA inserts caused up to 98% reduction in friction coefficient compared to original hip pairs. The application of PVA for local or even complete cartilage replacement seems to be an outstanding opportunity in implantology.
Název v anglickém jazyce
On the replacement of articular cartilage: The friction of PVA hydrogel layer in hip simulator test
Popis výsledku anglicky
The present study focuses on friction evaluation of the polyvinyl alcohol (PVA) hydrogel layer, an anticipative material for cartilage replacement. The experiments were carried out in a ball-in-socket configuration using a pendulum hip simulator. The friction coefficients of ceramic-on-hydrogel pairs were compared with those of commercial implants (metal/ceramic heads vs UHMWPE, HXPE and metal/ceramic sockets). The effects of hydrogel ageing and hydration were studied, among others. The use of PVA inserts caused up to 98% reduction in friction coefficient compared to original hip pairs. The application of PVA for local or even complete cartilage replacement seems to be an outstanding opportunity in implantology.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20301 - Mechanical engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Tribology International
ISSN
0301-679X
e-ISSN
1879-2464
Svazek periodika
178
Číslo periodika v rámci svazku
Neuveden
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
10
Strana od-do
—
Kód UT WoS článku
000928186200005
EID výsledku v databázi Scopus
2-s2.0-85142870449