Detector Timepix as a dosemeter of fast neutrons
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F14%3A%230000245" target="_blank" >RIV/86652052:_____/14:#0000245 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.dro2014.sk/files/zbornik_abstraktov.pdf" target="_blank" >http://www.dro2014.sk/files/zbornik_abstraktov.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Detector Timepix as a dosemeter of fast neutrons
Popis výsledku v původním jazyce
The pixelated detector Timepix is an unique detector of ionising particles with high position sensitivity. It provides an additional information about the type of detected particle using pattern recongnition analysis of clusters created from affected pixels. A Timepix detector covered with polyethylene convertors of different thicknesses is presented as a real-time dosemeter for measuring dose equivalents in fast neutron fields of unknown spectra. The application of such a dosemeter could be found in the control rooms of nuclear power plants, in research accelerators or for neutron dose estimation in proton therapy centres. The way of creating such a dosemeter is to apply different weighting factors on the collected signal from identified recoiled protons under particular convertors. We are presenting the first results of such a dosemeter calibrated under monoenergetic neutrons in National Physics Laboratory. An energy of neutron beam is in range 0.5-16.5 MeV. The results are compared
Název v anglickém jazyce
Detector Timepix as a dosemeter of fast neutrons
Popis výsledku anglicky
The pixelated detector Timepix is an unique detector of ionising particles with high position sensitivity. It provides an additional information about the type of detected particle using pattern recongnition analysis of clusters created from affected pixels. A Timepix detector covered with polyethylene convertors of different thicknesses is presented as a real-time dosemeter for measuring dose equivalents in fast neutron fields of unknown spectra. The application of such a dosemeter could be found in the control rooms of nuclear power plants, in research accelerators or for neutron dose estimation in proton therapy centres. The way of creating such a dosemeter is to apply different weighting factors on the collected signal from identified recoiled protons under particular convertors. We are presenting the first results of such a dosemeter calibrated under monoenergetic neutrons in National Physics Laboratory. An energy of neutron beam is in range 0.5-16.5 MeV. The results are compared
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/VF20102015014" target="_blank" >VF20102015014: Výzkum pokročilých metod detekce, stanovení a následné zvládnutí radioaktivní kontaminace</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů