Calibration of the Whole Body Counter for Measurement of Transuranium Elements in Lungs
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F14%3A%230000253" target="_blank" >RIV/86652052:_____/14:#0000253 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.dro2014.sk/files/zbornik_abstraktov.pdf" target="_blank" >http://www.dro2014.sk/files/zbornik_abstraktov.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Calibration of the Whole Body Counter for Measurement of Transuranium Elements in Lungs
Popis výsledku v původním jazyce
For purposes of in vivo measurements, two whole body counters (WBC) are operated in SÚRO. One of them was recently upgraded and equipped with new high efficient detectors. LLNL torso phantom was used for calibrations of the new WBC detection system. Thephantom is comprised with three pairs of replaceable lungs; one pair without activity, and two others with added 239Pu or 241Am activity. Considering the thickness and composition of the torso soft tissue, attenuating low energy photon radiation of transuranium elements, the phantom contains additional over layers of four different thickness simulating muscle and adipose tissue in ratio 1:1. Along with experimental calibrations of the WBC detection system using physical phantom, Monte Carlo technique has been used.
Název v anglickém jazyce
Calibration of the Whole Body Counter for Measurement of Transuranium Elements in Lungs
Popis výsledku anglicky
For purposes of in vivo measurements, two whole body counters (WBC) are operated in SÚRO. One of them was recently upgraded and equipped with new high efficient detectors. LLNL torso phantom was used for calibrations of the new WBC detection system. Thephantom is comprised with three pairs of replaceable lungs; one pair without activity, and two others with added 239Pu or 241Am activity. Considering the thickness and composition of the torso soft tissue, attenuating low energy photon radiation of transuranium elements, the phantom contains additional over layers of four different thickness simulating muscle and adipose tissue in ratio 1:1. Along with experimental calibrations of the WBC detection system using physical phantom, Monte Carlo technique has been used.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
DL - Jaderné odpady, radioaktivní znečištění a kontrola
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/VG20122014093" target="_blank" >VG20122014093: Systém pro měření vnitřní kontaminace po havárii JEZ zaměřený na štítné žlázy u dětí a kontaminaci transurany</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů