EURADOS intercomparison exercise on MC modeling for the in-vivo monitoring of 241Am in skull phantoms (Part I)
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F14%3A%230000255" target="_blank" >RIV/86652052:_____/14:#0000255 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.radphyschem.2013.12.010" target="_blank" >http://dx.doi.org/10.1016/j.radphyschem.2013.12.010</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.radphyschem.2013.12.010" target="_blank" >10.1016/j.radphyschem.2013.12.010</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
EURADOS intercomparison exercise on MC modeling for the in-vivo monitoring of 241Am in skull phantoms (Part I)
Popis výsledku v původním jazyce
An intercomparison on in-vivo monitoring for determination of Am-241 in three skull phantoms was launched by EURADOS in 2011. The project focused on the measurement and estimation of Am-241 activity in the human skull. Three human skull phantoms of different complexity were used. A Monte Carlo (MC) exercise with the voxel representations of the real phantoms was also launched in September 2012. The main goals of the project were to investigate the use of MC techniques for efficiency calibrations for body monitoring systems for a special calibration exercise and compare the approaches of participating laboratories. The full MC exercise consisted of three tasks with increasing difficulty, to test the extent of the skills of each participating laboratory.The first task in this intercomparison was to simulate a specified detector and a well defined semi-skull phantom. All parameters of the simulation, including photon yield, material property and geometry were fixed. This paper provides a
Název v anglickém jazyce
EURADOS intercomparison exercise on MC modeling for the in-vivo monitoring of 241Am in skull phantoms (Part I)
Popis výsledku anglicky
An intercomparison on in-vivo monitoring for determination of Am-241 in three skull phantoms was launched by EURADOS in 2011. The project focused on the measurement and estimation of Am-241 activity in the human skull. Three human skull phantoms of different complexity were used. A Monte Carlo (MC) exercise with the voxel representations of the real phantoms was also launched in September 2012. The main goals of the project were to investigate the use of MC techniques for efficiency calibrations for body monitoring systems for a special calibration exercise and compare the approaches of participating laboratories. The full MC exercise consisted of three tasks with increasing difficulty, to test the extent of the skills of each participating laboratory.The first task in this intercomparison was to simulate a specified detector and a well defined semi-skull phantom. All parameters of the simulation, including photon yield, material property and geometry were fixed. This paper provides a
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DL - Jaderné odpady, radioaktivní znečištění a kontrola
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/VG20122014093" target="_blank" >VG20122014093: Systém pro měření vnitřní kontaminace po havárii JEZ zaměřený na štítné žlázy u dětí a kontaminaci transurany</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Physics and Chemistry
ISSN
0969-806X
e-ISSN
—
Svazek periodika
104
Číslo periodika v rámci svazku
November
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
332-338
Kód UT WoS článku
000341463600070
EID výsledku v databázi Scopus
—