X-ray tube spectra measurement and correction using a CdTe detector and an analytic response matrix for photon energies up to 160 keV
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F16%3AN0000031" target="_blank" >RIV/86652052:_____/16:N0000031 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.radmeas.2015.12.008" target="_blank" >http://dx.doi.org/10.1016/j.radmeas.2015.12.008</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.radmeas.2015.12.008" target="_blank" >10.1016/j.radmeas.2015.12.008</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
X-ray tube spectra measurement and correction using a CdTe detector and an analytic response matrix for photon energies up to 160 keV
Popis výsledku v původním jazyce
The spectra of five “narrow-spectrum series” beams, namely N60 to N150, were measured with a spectrometry system consisting of the Amptek XR-100T X-ray semiconductor detector and the PX5 multichannel analyser. The response matrix R(E, E') of the detector was constructed which quantifies the energy dependence of the relative detection efficiency of the detector, the probabilities of the escape effects, and the probability of the Compton effect. A single matrix operation was applied to recover the physical energy spectra from the measured instrumental ones. The parameters of the corrected spectra were compared with the published and reference data. A fully satisfying quantitative correspondence was observed between the measured corrected spectra and the available reference data.
Název v anglickém jazyce
X-ray tube spectra measurement and correction using a CdTe detector and an analytic response matrix for photon energies up to 160 keV
Popis výsledku anglicky
The spectra of five “narrow-spectrum series” beams, namely N60 to N150, were measured with a spectrometry system consisting of the Amptek XR-100T X-ray semiconductor detector and the PX5 multichannel analyser. The response matrix R(E, E') of the detector was constructed which quantifies the energy dependence of the relative detection efficiency of the detector, the probabilities of the escape effects, and the probability of the Compton effect. A single matrix operation was applied to recover the physical energy spectra from the measured instrumental ones. The parameters of the corrected spectra were compared with the published and reference data. A fully satisfying quantitative correspondence was observed between the measured corrected spectra and the available reference data.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Measurements
ISSN
1350-4487
e-ISSN
—
Svazek periodika
85
Číslo periodika v rámci svazku
February
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
64-72
Kód UT WoS článku
000370089600008