The use of a CZT detector with robotic systems
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F20%3AN0000054" target="_blank" >RIV/86652052:_____/20:N0000054 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21670/20:00342793 RIV/68407700:21730/20:00342793
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/abs/pii/S0969804320305418" target="_blank" >https://www.sciencedirect.com/science/article/abs/pii/S0969804320305418</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.apradiso.2020.109395" target="_blank" >10.1016/j.apradiso.2020.109395</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The use of a CZT detector with robotic systems
Popis výsledku v původním jazyce
This work is focused on the use of a CZT detector for radiation mapping with an industrial robotic arm. Measurements were carried out within the RadioRoSo experiment (Radioactive Waste Robotic Sorter), under the umbrella of EU FP7 project ECHORD++. In tests with a dual-arm robot and standard point sources, Magnox waste was mimicked. Thereafter, for relevant measurement geometries and selected shielding materials, full-energy peak efficiencies were calculated using the MCNP transport code. Simulated FEP efficiency values were used for minimum detectable activity assessments for expected measurement conditions. Obtained results would be also applicable for cases of shielded lost/orphan point-like sources.
Název v anglickém jazyce
The use of a CZT detector with robotic systems
Popis výsledku anglicky
This work is focused on the use of a CZT detector for radiation mapping with an industrial robotic arm. Measurements were carried out within the RadioRoSo experiment (Radioactive Waste Robotic Sorter), under the umbrella of EU FP7 project ECHORD++. In tests with a dual-arm robot and standard point sources, Magnox waste was mimicked. Thereafter, for relevant measurement geometries and selected shielding materials, full-energy peak efficiencies were calculated using the MCNP transport code. Simulated FEP efficiency values were used for minimum detectable activity assessments for expected measurement conditions. Obtained results would be also applicable for cases of shielded lost/orphan point-like sources.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20305 - Nuclear related engineering; (nuclear physics to be 1.3);
Návaznosti výsledku
Projekt
<a href="/cs/project/TE01020197" target="_blank" >TE01020197: Centrum aplikované kybernetiky 3</a><br>
Návaznosti
R - Projekt Ramcoveho programu EK
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Radiation and Isotopes
ISSN
0969-8043
e-ISSN
1872-9800
Svazek periodika
166
Číslo periodika v rámci svazku
December
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
109395
Kód UT WoS článku
000589093400059
EID výsledku v databázi Scopus
2-s2.0-85090360997