Land Surface Temperature Differences within Local Climate Zones, Based on Two Central European Cities
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652079%3A_____%2F16%3A00466919" target="_blank" >RIV/86652079:_____/16:00466919 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14310/16:00090910 RIV/61989592:15310/16:33160760
Výsledek na webu
<a href="http://dx.doi.org/10.3390/rs8100788" target="_blank" >http://dx.doi.org/10.3390/rs8100788</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/rs8100788" target="_blank" >10.3390/rs8100788</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Land Surface Temperature Differences within Local Climate Zones, Based on Two Central European Cities
Popis výsledku v původním jazyce
The main factors influencing the spatiotemporal variability of urban climate are quite widely recognized, including, for example, the thermal properties of materials used for surfaces and buildings, the mass, height and layout of the buildings themselves and patterns of land use. However, the roles played by particular factors vary from city to city with respect to differences in geographical location, overall size, number of inhabitants and more. In urban climatology, the concept of local climate zones (LCZs) has emerged over the past decade to address this heterogeneity. In this contribution, a new GIS-based method is used for LCZ delimitation in Prague and Brno, the two largest cities in the Czech Republic, while land surface temperatures (LSTs) derived from LANDSAT and ASTER satellite data are employed for exploring the extent to which LCZ classes discriminate with respect to LSTs. It has been suggested that correctly-delineated LCZs should demonstrate the features typical of LST variability, and thus, typical surface temperatures should differ significantly among most LCZs. Zones representing heavy industry (LCZ 10), dense low-rise buildings (LCZ 3) and compact mid-rise buildings (LCZ 2) were identified as the warmest in both cities, while bodies of water (LCZ G) and densely-forested areas (LCZ A) made up the coolest zones. ANOVA and subsequent multiple comparison tests demonstrated that significant temperature differences between the various LCZs prevail. The results of testing were similar for both study areas (89.3% and 91.7% significant LST differences for Brno and Prague, respectively). LSTs computed from LANDSAT differentiated better between LCZs, compared with ASTER. LCZ 8 (large low-rise buildings), LCZ 10 (heavy industry) and LCZ D (low plants) are well-differentiated zones in terms of their surface temperatures. In contrast, LCZ 2 (compact mid-rise), LCZ 4 (open high-rise) and LCZ 9 (sparsely built-up) are less distinguishable in both areas analyzed.
Název v anglickém jazyce
Land Surface Temperature Differences within Local Climate Zones, Based on Two Central European Cities
Popis výsledku anglicky
The main factors influencing the spatiotemporal variability of urban climate are quite widely recognized, including, for example, the thermal properties of materials used for surfaces and buildings, the mass, height and layout of the buildings themselves and patterns of land use. However, the roles played by particular factors vary from city to city with respect to differences in geographical location, overall size, number of inhabitants and more. In urban climatology, the concept of local climate zones (LCZs) has emerged over the past decade to address this heterogeneity. In this contribution, a new GIS-based method is used for LCZ delimitation in Prague and Brno, the two largest cities in the Czech Republic, while land surface temperatures (LSTs) derived from LANDSAT and ASTER satellite data are employed for exploring the extent to which LCZ classes discriminate with respect to LSTs. It has been suggested that correctly-delineated LCZs should demonstrate the features typical of LST variability, and thus, typical surface temperatures should differ significantly among most LCZs. Zones representing heavy industry (LCZ 10), dense low-rise buildings (LCZ 3) and compact mid-rise buildings (LCZ 2) were identified as the warmest in both cities, while bodies of water (LCZ G) and densely-forested areas (LCZ A) made up the coolest zones. ANOVA and subsequent multiple comparison tests demonstrated that significant temperature differences between the various LCZs prevail. The results of testing were similar for both study areas (89.3% and 91.7% significant LST differences for Brno and Prague, respectively). LSTs computed from LANDSAT differentiated better between LCZs, compared with ASTER. LCZ 8 (large low-rise buildings), LCZ 10 (heavy industry) and LCZ D (low plants) are well-differentiated zones in terms of their surface temperatures. In contrast, LCZ 2 (compact mid-rise), LCZ 4 (open high-rise) and LCZ 9 (sparsely built-up) are less distinguishable in both areas analyzed.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
EH - Ekologie – společenstva
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1415" target="_blank" >LO1415: CzechGlobe 2020 - Rozvoj Centra pro studium dopadů globální změny klimatu</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Remote Sensing
ISSN
2072-4292
e-ISSN
—
Svazek periodika
8
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
18
Strana od-do
—
Kód UT WoS článku
000387357300002
EID výsledku v databázi Scopus
2-s2.0-84857124987