Levitronix centriMag pump as perioperative left ventricular support in a patient with critical aortic stenosis, mitral regurgitation, and cardiogenic shock
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F11%3A00002461" target="_blank" >RIV/00023001:_____/11:00002461 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1532/HSF98.20101070" target="_blank" >http://dx.doi.org/10.1532/HSF98.20101070</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1532/HSF98.20101070" target="_blank" >10.1532/HSF98.20101070</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Levitronix centriMag pump as perioperative left ventricular support in a patient with critical aortic stenosis, mitral regurgitation, and cardiogenic shock
Popis výsledku v původním jazyce
Severe aortic stenosis (AS) has a poor prognosis when associated with left ventricular dysfunction and congestive heart failure. Despite a relatively high operative mortality, most patients with severe AS and a depressed left ventricular ejection fraction (LVEF) should be considered candidates for aortic valve replacement. The CentriMag left ventricular assist system (Levitronix) can be used for perioperative or postcardiotomy circulatory support for the failing heart. In this report, we report the successful use of the Levitronix CentriMag device as perioperative support in a high-risk patient with severe AS, significant mitral insufficiency, and a poor LVEF with advanced organ failure
Název v anglickém jazyce
Levitronix centriMag pump as perioperative left ventricular support in a patient with critical aortic stenosis, mitral regurgitation, and cardiogenic shock
Popis výsledku anglicky
Severe aortic stenosis (AS) has a poor prognosis when associated with left ventricular dysfunction and congestive heart failure. Despite a relatively high operative mortality, most patients with severe AS and a depressed left ventricular ejection fraction (LVEF) should be considered candidates for aortic valve replacement. The CentriMag left ventricular assist system (Levitronix) can be used for perioperative or postcardiotomy circulatory support for the failing heart. In this report, we report the successful use of the Levitronix CentriMag device as perioperative support in a high-risk patient with severe AS, significant mitral insufficiency, and a poor LVEF with advanced organ failure
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Heart surgery forum
ISSN
1098-3511
e-ISSN
—
Svazek periodika
14
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
3
Strana od-do
"e64"-"e66"
Kód UT WoS článku
000287699600011
EID výsledku v databázi Scopus
—