The impact of left ventricle assist device on circulating endothelial microparticles - pilot study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F12%3A00057940" target="_blank" >RIV/00023001:_____/12:00057940 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.nel.edu/home.htm" target="_blank" >http://www.nel.edu/home.htm</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The impact of left ventricle assist device on circulating endothelial microparticles - pilot study
Popis výsledku v původním jazyce
OBJECTIVES: Recent technological breakthroughs in the design of reliable systems for long term non-pulsatile mechanical heart support offer the possibility to study the effect of continuous blood flow in the vascular system. Generally, it is assumed thatthe absence of physiological pulsatile flow leads to prothrombogenic and proatherogenic changes. We investigated the change in the circulating endothelial microparticle concentration as a marker of endothelial damage in patients implanted with a continuous-flow left ventricle assist device (LVAD). METHODS: Endothelial microparticles were measured in 8 males (mean age 54.1 +/- 11.5 years) with terminal heart failure before and 3 months after implantation of an LVAD. The group consisted of 3 patients with dilated cardiomyopathy, 3 patients with ischemic cardiomyopathy, 1 patient with both conditions and 1 patient with congenital valvular disease. The concentration of endothelial microparticles was determined by ELISA Zymutest MP activity
Název v anglickém jazyce
The impact of left ventricle assist device on circulating endothelial microparticles - pilot study
Popis výsledku anglicky
OBJECTIVES: Recent technological breakthroughs in the design of reliable systems for long term non-pulsatile mechanical heart support offer the possibility to study the effect of continuous blood flow in the vascular system. Generally, it is assumed thatthe absence of physiological pulsatile flow leads to prothrombogenic and proatherogenic changes. We investigated the change in the circulating endothelial microparticle concentration as a marker of endothelial damage in patients implanted with a continuous-flow left ventricle assist device (LVAD). METHODS: Endothelial microparticles were measured in 8 males (mean age 54.1 +/- 11.5 years) with terminal heart failure before and 3 months after implantation of an LVAD. The group consisted of 3 patients with dilated cardiomyopathy, 3 patients with ischemic cardiomyopathy, 1 patient with both conditions and 1 patient with congenital valvular disease. The concentration of endothelial microparticles was determined by ELISA Zymutest MP activity
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Neuroendocrinology letters
ISSN
0172-780X
e-ISSN
—
Svazek periodika
33
Číslo periodika v rámci svazku
suppl. 2
Stát vydavatele periodika
SE - Švédské království
Počet stran výsledku
5
Strana od-do
68-72
Kód UT WoS článku
000312175400013
EID výsledku v databázi Scopus
—