Endothelial Dysfunction Expressed as Endothelial Microparticles in Patients With End-Stage Heart Failure
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F14%3A00061370" target="_blank" >RIV/00159816:_____/14:00061370 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11120/14:43909173 RIV/00023001:_____/14:00059111
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Endothelial Dysfunction Expressed as Endothelial Microparticles in Patients With End-Stage Heart Failure
Popis výsledku v původním jazyce
Left ventricular assist devices (LVAD), currently used in treatment of terminal heart failure, are working on principle of rotary pump, which generates continuous blood flow. Non-pulsatile flow is supposed to expose endothelial cells to high stress and potential damage. Therefore, we investigated longitudinal changes in concentration of circulating endothelial microparticles (EMP) as a possible marker of endothelial damage before and after implantation of LVAD. Study population comprised 30 patients with end-stage heart failure indicated for implantation of the Heart Mate II LVAD. Concentrations of microparticles were measured as nanomoles per liter relative to phosphatidylserine before and 3 months after implantation. At 3 months after implantation weobserved significant decrease in concentration of EMP [5.89 (95 % CI 4.31-8.03) vs. 3.69 (95 % CI 2.70-5.03), p= 0.03] in the whole group; there was no difference observed between patients with ischemic etiology of heart failure (n= 18)
Název v anglickém jazyce
Endothelial Dysfunction Expressed as Endothelial Microparticles in Patients With End-Stage Heart Failure
Popis výsledku anglicky
Left ventricular assist devices (LVAD), currently used in treatment of terminal heart failure, are working on principle of rotary pump, which generates continuous blood flow. Non-pulsatile flow is supposed to expose endothelial cells to high stress and potential damage. Therefore, we investigated longitudinal changes in concentration of circulating endothelial microparticles (EMP) as a possible marker of endothelial damage before and after implantation of LVAD. Study population comprised 30 patients with end-stage heart failure indicated for implantation of the Heart Mate II LVAD. Concentrations of microparticles were measured as nanomoles per liter relative to phosphatidylserine before and 3 months after implantation. At 3 months after implantation weobserved significant decrease in concentration of EMP [5.89 (95 % CI 4.31-8.03) vs. 3.69 (95 % CI 2.70-5.03), p= 0.03] in the whole group; there was no difference observed between patients with ischemic etiology of heart failure (n= 18)
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
ED - Fyziologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physiological Research
ISSN
0862-8408
e-ISSN
—
Svazek periodika
63
Číslo periodika v rámci svazku
S3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
"S369"-"S373"
Kód UT WoS článku
000345591100007
EID výsledku v databázi Scopus
—