Stroke outcomes following durable left ventricular assist device implant in patients bridged with micro-axial flow pump: insights from a large registry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F24%3A00085049" target="_blank" >RIV/00023001:_____/24:00085049 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/24:10482904 RIV/00064165:_____/24:10482904
Výsledek na webu
<a href="https://www.webofscience.com/wos/woscc/full-record/WOS:001232142500001" target="_blank" >https://www.webofscience.com/wos/woscc/full-record/WOS:001232142500001</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1111/aor.14775" target="_blank" >10.1111/aor.14775</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Stroke outcomes following durable left ventricular assist device implant in patients bridged with micro-axial flow pump: insights from a large registry
Popis výsledku v původním jazyce
Background: Stroke after durable left ventricular assist device (d-LVAD) implantation portends high mortality. The incidence of ischemic and hemorrhagic stroke and the impact on stroke outcomes of temporary mechanical circulatory support (tMCS) management among patients requiring bridge to d-LVAD with micro-axial flow-pump (mAFP, Abiomed) is unsettled. Methods: Consecutive patients, who underwent d-LVAD implantation after being bridged with mAFP at 19 institutions, were retrospectively included. The incidence of early ischemic and hemorrhagic stroke after d-LVAD implantation (<60 days) and association of pre-d-LVAD characteristics and peri-procedural management with a specific focus on tMCS strategies were studied. Results: Among 341 patients, who underwent d-LVAD implantation after mAFP implantation (male gender 83.6%, age 58 [48-65] years, mAFP 5.0/5.5 72.4%), the early ischemic stroke incidence was 10.8% and early hemorrhagic stroke 2.9%. The tMCS characteristics (type of mAFP device and access, support duration, upgrade from intra-aortic balloon pump, ECMELLA, ECMELLA at d-LVAD implantation, hemolysis, and bleeding) were not associated with ischemic stroke after d-LVAD implant. Conversely, the device model (mAFP 2.5/CP vs. mAFP 5.0/5.5: HR 5.6, 95%CI 1.4-22.7, p = 0.015), hemolysis on mAFP support (HR 10.5, 95% CI 1.3-85.3, p = 0.028) and ECMELLA at d-LVAD implantation (HR 5.0, 95% CI 1.4-18.7, p = 0.016) were associated with increased risk of hemorrhagic stroke after d-LVAD implantation. Both early ischemic (HR 2.7, 95% CI 1.9-4.5, p < 0.001) and hemorrhagic (HR 3.43, 95% CI 1.49-7.88, p = 0.004) stroke were associated with increased 1-year mortality. Conclusions: Among patients undergoing d-LVAD implantation following mAFP support, tMCS characteristics do not impact ischemic stroke occurrence, while several factors are associated with hemorrhagic stroke suggesting a proactive treatment target to reduce this complication.
Název v anglickém jazyce
Stroke outcomes following durable left ventricular assist device implant in patients bridged with micro-axial flow pump: insights from a large registry
Popis výsledku anglicky
Background: Stroke after durable left ventricular assist device (d-LVAD) implantation portends high mortality. The incidence of ischemic and hemorrhagic stroke and the impact on stroke outcomes of temporary mechanical circulatory support (tMCS) management among patients requiring bridge to d-LVAD with micro-axial flow-pump (mAFP, Abiomed) is unsettled. Methods: Consecutive patients, who underwent d-LVAD implantation after being bridged with mAFP at 19 institutions, were retrospectively included. The incidence of early ischemic and hemorrhagic stroke after d-LVAD implantation (<60 days) and association of pre-d-LVAD characteristics and peri-procedural management with a specific focus on tMCS strategies were studied. Results: Among 341 patients, who underwent d-LVAD implantation after mAFP implantation (male gender 83.6%, age 58 [48-65] years, mAFP 5.0/5.5 72.4%), the early ischemic stroke incidence was 10.8% and early hemorrhagic stroke 2.9%. The tMCS characteristics (type of mAFP device and access, support duration, upgrade from intra-aortic balloon pump, ECMELLA, ECMELLA at d-LVAD implantation, hemolysis, and bleeding) were not associated with ischemic stroke after d-LVAD implant. Conversely, the device model (mAFP 2.5/CP vs. mAFP 5.0/5.5: HR 5.6, 95%CI 1.4-22.7, p = 0.015), hemolysis on mAFP support (HR 10.5, 95% CI 1.3-85.3, p = 0.028) and ECMELLA at d-LVAD implantation (HR 5.0, 95% CI 1.4-18.7, p = 0.016) were associated with increased risk of hemorrhagic stroke after d-LVAD implantation. Both early ischemic (HR 2.7, 95% CI 1.9-4.5, p < 0.001) and hemorrhagic (HR 3.43, 95% CI 1.49-7.88, p = 0.004) stroke were associated with increased 1-year mortality. Conclusions: Among patients undergoing d-LVAD implantation following mAFP support, tMCS characteristics do not impact ischemic stroke occurrence, while several factors are associated with hemorrhagic stroke suggesting a proactive treatment target to reduce this complication.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Artificial organs
ISSN
0160-564X
e-ISSN
1525-1594
Svazek periodika
48
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
12
Strana od-do
1168-1179
Kód UT WoS článku
001232142500001
EID výsledku v databázi Scopus
2-s2.0-85194873075