Determination of the purity of ampicillin by micellar electrokinetic chromatography and reversed phase liquid chromatography on a monolithic silica column
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023817%3A_____%2F04%3A%230000002" target="_blank" >RIV/00023817:_____/04:#0000002 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1002/jssc.200301680" target="_blank" >http://dx.doi.org/10.1002/jssc.200301680</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/jssc.200301680" target="_blank" >10.1002/jssc.200301680</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of the purity of ampicillin by micellar electrokinetic chromatography and reversed phase liquid chromatography on a monolithic silica column
Popis výsledku v původním jazyce
A micellar electrokinetic chromatographic (MEKC) method and a fast reversed-phase liquid chromatographic one have been developed for determining the purity of ampicillin. MEKC separation of ampicillin and its related substances was performed with the useof an untreated fused-silica capillary and 40 mM phosphate-borate buffer, pH 7.5 containing 75 mM SDS. The HPLC method employed a monolithic silica C18 column and a mobile phase composed of phosphate buffer, pH 5.2 and ACN, the flow rate being 4.0 mL/min. Both methods were successfully validated. Linearity, relative response factors, limits of quantitation, intermediate precision, and accuracy were evaluated. The methods proved to be fast, reliable, and sufficiently sensitive and, accordingly, well-suited for control of purity of ampicillin substance, injections, and capsules. A combination of both methods can be very useful in the confirmation of impurity profiles.
Název v anglickém jazyce
Determination of the purity of ampicillin by micellar electrokinetic chromatography and reversed phase liquid chromatography on a monolithic silica column
Popis výsledku anglicky
A micellar electrokinetic chromatographic (MEKC) method and a fast reversed-phase liquid chromatographic one have been developed for determining the purity of ampicillin. MEKC separation of ampicillin and its related substances was performed with the useof an untreated fused-silica capillary and 40 mM phosphate-borate buffer, pH 7.5 containing 75 mM SDS. The HPLC method employed a monolithic silica C18 column and a mobile phase composed of phosphate buffer, pH 5.2 and ACN, the flow rate being 4.0 mL/min. Both methods were successfully validated. Linearity, relative response factors, limits of quantitation, intermediate precision, and accuracy were evaluated. The methods proved to be fast, reliable, and sufficiently sensitive and, accordingly, well-suited for control of purity of ampicillin substance, injections, and capsules. A combination of both methods can be very useful in the confirmation of impurity profiles.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NL5965" target="_blank" >NL5965: Kontrola obsahu příbuzných látek amoxicilinu,ampicilinu,fenoxymethylpenicilinu v léčivých přípravcích za použití metod HPLC a CE</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of separation science
ISSN
1615-9314
e-ISSN
—
Svazek periodika
27
Číslo periodika v rámci svazku
7-8
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
9
Strana od-do
560-568
Kód UT WoS článku
000221547900012