Worldwide Chronic Retrieval Experience of Helix-Fixation Leadless Cardiac Pacemakers
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F25%3A00010195" target="_blank" >RIV/00023884:_____/25:00010195 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0735109724102926?pes=vor&utm_source=clarivate&getft_integrator=clarivate" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0735109724102926?pes=vor&utm_source=clarivate&getft_integrator=clarivate</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jacc.2024.10.094" target="_blank" >10.1016/j.jacc.2024.10.094</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Worldwide Chronic Retrieval Experience of Helix-Fixation Leadless Cardiac Pacemakers
Popis výsledku v původním jazyce
BACKGROUND: The growing use of leadless pacemaker (LP) technology requires safe and effective solutions for retrieving and removing these devices over the long term. OBJECTIVES This study sought to evaluate retrieval and removal of an active helix-fixation LP studied in worldwide regulatory clinical trials. METHODS Subjects enrolled in the LEADLESS II phase 1 investigational device exemption, LEADLESS Observational, or LEADLESS Japan trials with an attempted LP retrieval at least 6 weeks postimplantation were included. The retrieval success rate was evaluated for all attempted retrievals. Site-reported complications associated with LP retrievals were quantified, with the severity and relationship adjudicated by an independent clinical events committee. RESULTS There were 1,423 successful LP implants and 234 chronic LP retrieval attempts in 233 subjects. The overall retrieval success rate was 87.6% (205 of 234 attempts). The most common reason for failed retrieval (86.2%, 25 of 29 attempts) was inability to access the LP docking button. The mean time from implantation to attempted retrieval was 3.2 years (range 0.2-9.0 years) and did not significantly influence the retrieval success (P 1/4 0.71). The clinical events committee adjudicated 11 complications in 9 subjects as being retrieval related (3.9%, 9 of 233 subjects). CONCLUSIONS The safety and efficacy of chronic LP retrieval of an active helix-fixation device was demonstrated in an international clinical trial setting, with implant durations up to 9 years. (JACC. 2025;85:1111-1120) (c) 2025 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
Název v anglickém jazyce
Worldwide Chronic Retrieval Experience of Helix-Fixation Leadless Cardiac Pacemakers
Popis výsledku anglicky
BACKGROUND: The growing use of leadless pacemaker (LP) technology requires safe and effective solutions for retrieving and removing these devices over the long term. OBJECTIVES This study sought to evaluate retrieval and removal of an active helix-fixation LP studied in worldwide regulatory clinical trials. METHODS Subjects enrolled in the LEADLESS II phase 1 investigational device exemption, LEADLESS Observational, or LEADLESS Japan trials with an attempted LP retrieval at least 6 weeks postimplantation were included. The retrieval success rate was evaluated for all attempted retrievals. Site-reported complications associated with LP retrievals were quantified, with the severity and relationship adjudicated by an independent clinical events committee. RESULTS There were 1,423 successful LP implants and 234 chronic LP retrieval attempts in 233 subjects. The overall retrieval success rate was 87.6% (205 of 234 attempts). The most common reason for failed retrieval (86.2%, 25 of 29 attempts) was inability to access the LP docking button. The mean time from implantation to attempted retrieval was 3.2 years (range 0.2-9.0 years) and did not significantly influence the retrieval success (P 1/4 0.71). The clinical events committee adjudicated 11 complications in 9 subjects as being retrieval related (3.9%, 9 of 233 subjects). CONCLUSIONS The safety and efficacy of chronic LP retrieval of an active helix-fixation device was demonstrated in an international clinical trial setting, with implant durations up to 9 years. (JACC. 2025;85:1111-1120) (c) 2025 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of the American College of Cardiology
ISSN
0735-1097
e-ISSN
—
Svazek periodika
85
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
1111-1120
Kód UT WoS článku
001486907500001
EID výsledku v databázi Scopus
2-s2.0-86000432190