Comparison of routine contrast-enhanced computed tomography with late gadolinium enhancement cardiac magnetic resonance imaging in the detection of myocardial pathology
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F19%3A10400968" target="_blank" >RIV/00064165:_____/19:10400968 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/19:10400968
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=QU_xSne4i1" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=QU_xSne4i1</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.33963/KP.14928" target="_blank" >10.33963/KP.14928</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of routine contrast-enhanced computed tomography with late gadolinium enhancement cardiac magnetic resonance imaging in the detection of myocardial pathology
Popis výsledku v původním jazyce
Background: Cardiac magnetic resonance imaging (MRI) represents the gold standard in noninvasive evaluation of myocardial tissue. However, some patients are unable to undergo cardiac MRI due to a variety of reasons. Aims: We sought to determine the diagnostic accuracy of routinely performed contrast-enhanced computed tomography (CECT) compared with cardiac MRI in the evaluation of myocardial tissue. Methods: We retrospectively evaluated 96 consecutive patients (mean [SD] age, 51 [15] years; 41 women) who underwent both CECT and cardiac MRI within 30 days. All CECT scans that visualized the entire heart were analyzed, regardless of the indication for and protocol of the procedure. The presence of late gadolinium enhancement on cardiac MRI was compared with the finding of myocardial hypoattenuation on computed tomography scans. Results: With cardiac MRI as the gold standard, CECT revealed a per-patient sensitivity of 66%, specificity of 89%, positive predictive value of 75%, negative predictive value of 84%, and accuracy of 81%. Per-segment sensitivity was 54%; specificity, 98%; positive predictive value, 76%; negative predictive value, 94%; and accuracy, 92%. Conclusions: Our study suggests that routinely performed CECT has high specificity, but only moderate sensitivity, compared with cardiac MRI in the evaluation of myocardial tissue. This result supports the recommendation that all CECT scans that visualize the entire heart should be analyzed for myocardial tissue pathology.
Název v anglickém jazyce
Comparison of routine contrast-enhanced computed tomography with late gadolinium enhancement cardiac magnetic resonance imaging in the detection of myocardial pathology
Popis výsledku anglicky
Background: Cardiac magnetic resonance imaging (MRI) represents the gold standard in noninvasive evaluation of myocardial tissue. However, some patients are unable to undergo cardiac MRI due to a variety of reasons. Aims: We sought to determine the diagnostic accuracy of routinely performed contrast-enhanced computed tomography (CECT) compared with cardiac MRI in the evaluation of myocardial tissue. Methods: We retrospectively evaluated 96 consecutive patients (mean [SD] age, 51 [15] years; 41 women) who underwent both CECT and cardiac MRI within 30 days. All CECT scans that visualized the entire heart were analyzed, regardless of the indication for and protocol of the procedure. The presence of late gadolinium enhancement on cardiac MRI was compared with the finding of myocardial hypoattenuation on computed tomography scans. Results: With cardiac MRI as the gold standard, CECT revealed a per-patient sensitivity of 66%, specificity of 89%, positive predictive value of 75%, negative predictive value of 84%, and accuracy of 81%. Per-segment sensitivity was 54%; specificity, 98%; positive predictive value, 76%; negative predictive value, 94%; and accuracy, 92%. Conclusions: Our study suggests that routinely performed CECT has high specificity, but only moderate sensitivity, compared with cardiac MRI in the evaluation of myocardial tissue. This result supports the recommendation that all CECT scans that visualize the entire heart should be analyzed for myocardial tissue pathology.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30224 - Radiology, nuclear medicine and medical imaging
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Kardiologia Polska
ISSN
0022-9032
e-ISSN
—
Svazek periodika
77
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
7
Strana od-do
944-950
Kód UT WoS článku
000492832400008
EID výsledku v databázi Scopus
2-s2.0-85074118797