Distal locking in short hip nails: Cause or prevention of peri-implant fractures?
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064173%3A_____%2F16%3AN0000022" target="_blank" >RIV/00064173:_____/16:N0000022 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11120/16:43911131
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.injury.2016.02.009" target="_blank" >http://dx.doi.org/10.1016/j.injury.2016.02.009</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.injury.2016.02.009" target="_blank" >10.1016/j.injury.2016.02.009</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Distal locking in short hip nails: Cause or prevention of peri-implant fractures?
Popis výsledku v původním jazyce
OBJECTIVES: The most common cause of femoral fractures after osteosynthesis of trochanteric fractures with short nails is weakening of the femoral cortex via distal locking and stress concentrations at the tip of the nail. The aim of the study was to verify whether the incidence of peri-implant fractures is dependent upon the distal locking technique. METHODS: We prospectively analysed a group of 849 pertrochanteric fractures (AO/ASIF 31-A1+2) managed with short nails from 2009 to 2013. Unlocked nailing was performed in 70.1% and distal dynamic locking was performed in 29.9%. The mean age was 82.0 years. Peri-implant fractures were divided into 3 groups according to the height of the fracture in relation to the tip of the nail. RESULTS: In total 17 fractures (2.0%) were detected. One peri-implant fracture occurred after locked nailing, whereas 16 cases occurred after unlocked nailing (p=0.037). Patients without distal locking had an 85.7% greater risk of peri-implant fracture. Fractures of the proximal femur (Type I) occurred significantly earlier than fractures at the tip of the nail (Type II) (p=0.028). CONCLUSION: Unlocked nails do not guarantee sufficient stability. Distal locking serves to prevent postoperative femoral fractures. We recommend the routine use of distal locking when utilizing short nails.
Název v anglickém jazyce
Distal locking in short hip nails: Cause or prevention of peri-implant fractures?
Popis výsledku anglicky
OBJECTIVES: The most common cause of femoral fractures after osteosynthesis of trochanteric fractures with short nails is weakening of the femoral cortex via distal locking and stress concentrations at the tip of the nail. The aim of the study was to verify whether the incidence of peri-implant fractures is dependent upon the distal locking technique. METHODS: We prospectively analysed a group of 849 pertrochanteric fractures (AO/ASIF 31-A1+2) managed with short nails from 2009 to 2013. Unlocked nailing was performed in 70.1% and distal dynamic locking was performed in 29.9%. The mean age was 82.0 years. Peri-implant fractures were divided into 3 groups according to the height of the fracture in relation to the tip of the nail. RESULTS: In total 17 fractures (2.0%) were detected. One peri-implant fracture occurred after locked nailing, whereas 16 cases occurred after unlocked nailing (p=0.037). Patients without distal locking had an 85.7% greater risk of peri-implant fracture. Fractures of the proximal femur (Type I) occurred significantly earlier than fractures at the tip of the nail (Type II) (p=0.028). CONCLUSION: Unlocked nails do not guarantee sufficient stability. Distal locking serves to prevent postoperative femoral fractures. We recommend the routine use of distal locking when utilizing short nails.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FI - Traumatologie a ortopedie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/TH01020049" target="_blank" >TH01020049: FEMUR</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Injury
ISSN
0020-1383
e-ISSN
—
Svazek periodika
47
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
887-892
Kód UT WoS článku
000375056400018
EID výsledku v databázi Scopus
2-s2.0-84959473569