The Influence of 7-OH Methotrexate Metabolite on Clinical Relevance of Methotrexate Determination
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F11%3A7117" target="_blank" >RIV/00064203:_____/11:7117 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11130/11:7117 RIV/68407700:21460/11:00228143
Výsledek na webu
<a href="http://www.ncbi.nlm.nih.gov/pubmed/21888024" target="_blank" >http://www.ncbi.nlm.nih.gov/pubmed/21888024</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Influence of 7-OH Methotrexate Metabolite on Clinical Relevance of Methotrexate Determination
Popis výsledku v původním jazyce
Background: A modified high performance liquid chromatographic (HPLC) method has been developed for the simultaneous determination of methotrexate (MTX) and its main metabolite 7-hydroxymethotrexate (7-OHMTX) and compared to the immunochemical fluorescence polarization immunoassay (FPIA2) determination of methotrexate. Methods: Methotrexate was determined by HPLC with UV detection at 303 nm after precipitation of proteins with trichloroacetic acid. Fluorescence polarization immunoassays (FPIA2) of methotrexate were performed on the TDx FLx Immunoassay Analyzer. Results: Our data indicate good correlation between methotrexate levels >1 mu mol/L determined by HPLC and FPIA2. (r = 0.94, Spearman correlation coefficient). However, concentrations of methotrexate <1 mu mol/L measured by fluorescence polarization immunoassay were overestimated. Conclusions: The concentration of MTX <1 mu mol/L are overestimated due to the cross reactivity with metabolites 7-OHMTX and 2,4-diamino-N(10)-methylp
Název v anglickém jazyce
The Influence of 7-OH Methotrexate Metabolite on Clinical Relevance of Methotrexate Determination
Popis výsledku anglicky
Background: A modified high performance liquid chromatographic (HPLC) method has been developed for the simultaneous determination of methotrexate (MTX) and its main metabolite 7-hydroxymethotrexate (7-OHMTX) and compared to the immunochemical fluorescence polarization immunoassay (FPIA2) determination of methotrexate. Methods: Methotrexate was determined by HPLC with UV detection at 303 nm after precipitation of proteins with trichloroacetic acid. Fluorescence polarization immunoassays (FPIA2) of methotrexate were performed on the TDx FLx Immunoassay Analyzer. Results: Our data indicate good correlation between methotrexate levels >1 mu mol/L determined by HPLC and FPIA2. (r = 0.94, Spearman correlation coefficient). However, concentrations of methotrexate <1 mu mol/L measured by fluorescence polarization immunoassay were overestimated. Conclusions: The concentration of MTX <1 mu mol/L are overestimated due to the cross reactivity with metabolites 7-OHMTX and 2,4-diamino-N(10)-methylp
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Clinical Laboratory
ISSN
1433-6510
e-ISSN
—
Svazek periodika
57
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
8
Strana od-do
599-606
Kód UT WoS článku
000295251000017
EID výsledku v databázi Scopus
—