Sensitive voltammetric method for determination of chemotherapeutic drug methotrexate using liquid mercury free silver solid amalgam electrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F14%3A39898015" target="_blank" >RIV/00216275:25310/14:39898015 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Sensitive voltammetric method for determination of chemotherapeutic drug methotrexate using liquid mercury free silver solid amalgam electrode
Popis výsledku v původním jazyce
Voltammetric behavior of a wide-spread used chemotherapeutic drug methotrexate (MTX) has been investigated on a polished silver solid amalgam electrode (p-AgSAE) employing various voltammetric methods like cyclic voltammetry, direct current voltammetry and differential pulse voltammetry. It was found that MTX provided two reduction and one oxidation peak in an acidic medium and the positively situated reduction signal (Ep = -340 mV), due its favorable analytical properties, was studied more in detail. 0.05 mol L-1 acetate buffer of pH 5 was selected as an optimal medium for monitoring of the MTX reduction on p-AgSAE. Operating parameters of differential pulse voltammetry were optimized and proposed voltammetric method provided high repeatability (relative standard deviation of 11 repeated measurements at concentration level of methotrexate of 1x10-7 mol L-1 equaled to 1.7%), linear concentration range from 5x10-10 to 3x10-6 mol L-1 and low limit of detection (LD = 1.5x10-10 mol L-1). T
Název v anglickém jazyce
Sensitive voltammetric method for determination of chemotherapeutic drug methotrexate using liquid mercury free silver solid amalgam electrode
Popis výsledku anglicky
Voltammetric behavior of a wide-spread used chemotherapeutic drug methotrexate (MTX) has been investigated on a polished silver solid amalgam electrode (p-AgSAE) employing various voltammetric methods like cyclic voltammetry, direct current voltammetry and differential pulse voltammetry. It was found that MTX provided two reduction and one oxidation peak in an acidic medium and the positively situated reduction signal (Ep = -340 mV), due its favorable analytical properties, was studied more in detail. 0.05 mol L-1 acetate buffer of pH 5 was selected as an optimal medium for monitoring of the MTX reduction on p-AgSAE. Operating parameters of differential pulse voltammetry were optimized and proposed voltammetric method provided high repeatability (relative standard deviation of 11 repeated measurements at concentration level of methotrexate of 1x10-7 mol L-1 equaled to 1.7%), linear concentration range from 5x10-10 to 3x10-6 mol L-1 and low limit of detection (LD = 1.5x10-10 mol L-1). T
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/EE2.3.30.0021" target="_blank" >EE2.3.30.0021: Posílení excelentních týmů výzkumu a vývoje na Univerzitě Pardubice</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Scientific Papers of the University of Pardubice, Series A, Faculty of Chemical Technology
ISSN
1211-5541
e-ISSN
—
Svazek periodika
20
Číslo periodika v rámci svazku
září 2014
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
16
Strana od-do
131-146
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—