Sensitive Voltammetric Sensor Based on Boron-Doped Diamond Electrode for Determination of the Chemotherapeutic Drug Methotrexate in Pharmaceutical and Biological Samples
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F15%3A39900150" target="_blank" >RIV/00216275:25310/15:39900150 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1002/elan.201400326" target="_blank" >http://dx.doi.org/10.1002/elan.201400326</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.201400326" target="_blank" >10.1002/elan.201400326</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Sensitive Voltammetric Sensor Based on Boron-Doped Diamond Electrode for Determination of the Chemotherapeutic Drug Methotrexate in Pharmaceutical and Biological Samples
Popis výsledku v původním jazyce
A novel sensitive voltammetric method for the determination of an important chemotherapeutic drug, methotrexate, was designed using a bare boron-doped diamond electrode in connection with differential pulse voltammetry. Methotrexate provided one well developed oxidation peak suitable for analytical purposes at about + 1000 mV (vs. Ag/AgCl electrode) in an acidic medium. The voltammetric behavior of methotrexate in dependence of pH of the supporting electrolyte and scan rate has been investigated using cyclic voltammetry and DC voltammetry, respectively, to select the suitable experimental parameters. The optimum conditions for its determination using differential pulse voltammetry have been found to be 0.05 mol L-1 H2SO4 with a limit of detection of 1.0 x 10(-8) mol L-1 and a linear dynamic range from 5 x 10(-8) to 2 x 10(-5) mol L-1. Calculated values of relative standard deviations of repeated determinations (n }= 5) in various concentration levels of methotrexate did not exceed 4%.
Název v anglickém jazyce
Sensitive Voltammetric Sensor Based on Boron-Doped Diamond Electrode for Determination of the Chemotherapeutic Drug Methotrexate in Pharmaceutical and Biological Samples
Popis výsledku anglicky
A novel sensitive voltammetric method for the determination of an important chemotherapeutic drug, methotrexate, was designed using a bare boron-doped diamond electrode in connection with differential pulse voltammetry. Methotrexate provided one well developed oxidation peak suitable for analytical purposes at about + 1000 mV (vs. Ag/AgCl electrode) in an acidic medium. The voltammetric behavior of methotrexate in dependence of pH of the supporting electrolyte and scan rate has been investigated using cyclic voltammetry and DC voltammetry, respectively, to select the suitable experimental parameters. The optimum conditions for its determination using differential pulse voltammetry have been found to be 0.05 mol L-1 H2SO4 with a limit of detection of 1.0 x 10(-8) mol L-1 and a linear dynamic range from 5 x 10(-8) to 2 x 10(-5) mol L-1. Calculated values of relative standard deviations of repeated determinations (n }= 5) in various concentration levels of methotrexate did not exceed 4%.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/EE2.3.30.0021" target="_blank" >EE2.3.30.0021: Posílení excelentních týmů výzkumu a vývoje na Univerzitě Pardubice</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
27
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
10
Strana od-do
42-51
Kód UT WoS článku
000347838300006
EID výsledku v databázi Scopus
—