Serum IL-6 in combination with synovial IL-6/CRP shows excellent diagnostic power to detect hip and knee prosthetic joint infection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00098892%3A_____%2F18%3AN0000012" target="_blank" >RIV/00098892:_____/18:N0000012 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989592:15110/18:73587456
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Serum IL-6 in combination with synovial IL-6/CRP shows excellent diagnostic power to detect hip and knee prosthetic joint infection
Popis výsledku v původním jazyce
Background: The diagnosis of prosthetic joint infection (PJI) is still a challenge in some patients after total joint replacement. Interleukin-6 (IL-6) strongly participates in the arrangement of the host-bacteria response. Therefore, increased levels of IL-6 should accompany every PJI. Purpose: The aim of the study was to show diagnostic characteristics of serum IL-6 for the diagnosis of prosthetic joint infection (PJI). We also compared the diagnostic values of serum IL-6 with synovial IL-6 (sIL-6) and synovial C-reactive protein (sCRP). Study design: We performed a prospective study of 240 patients in whom serum IL-6 was determined before total hip (n = 124) or knee (n = 116) reoperations. The PJI diagnosis was based on the MSIS (Musculoskeletal Infection Society) criteria (2011). Receiver operating characteristic plots were constructed for IL-6, sIL-6, and sCRP. Results: PJI was diagnosed in 93 patients, and aseptic revision was diagnosed in 147 patients. The AUC (area under curve) for IL-6 was 0.938 (95% CI; 0.904–0.971). The optimal IL-6 cut-off value for PJI was 12.55 ng/L. Positive and negative likelihood ratios for IL-6 were 8.24 (95% CI; 4.79–14.17) and 0.15 (95% CI; 0.09–0.26), respectively. The optimal sIL-6 and sCRP cut-off values were 20,988 ng/L and 8.80 mg/L, respectively. Positive and negative likelihood ratios for sIL-6 were 40.000 (95% CI; 5.7–280.5) and 0.170 (95% CI; 0.07–0.417), respectively. Negative likelihood ratio for sCRP was 0.083 (95% CI; 0.022–0.314). Conclusions: The present study identified the cut-off values for serum/synovial IL-6 and synovial CRP for diagnostics of PJI at the site of THA and TKA and separately for each site. The diagnostic odds ratio for serum/synovial IL-6 and synovial CRP is very good. Simultaneous positivity of serum IL-6 either with synovial IL-6 or synovial CRP almost excludes false negative detection of PJI at the site of interest.
Název v anglickém jazyce
Serum IL-6 in combination with synovial IL-6/CRP shows excellent diagnostic power to detect hip and knee prosthetic joint infection
Popis výsledku anglicky
Background: The diagnosis of prosthetic joint infection (PJI) is still a challenge in some patients after total joint replacement. Interleukin-6 (IL-6) strongly participates in the arrangement of the host-bacteria response. Therefore, increased levels of IL-6 should accompany every PJI. Purpose: The aim of the study was to show diagnostic characteristics of serum IL-6 for the diagnosis of prosthetic joint infection (PJI). We also compared the diagnostic values of serum IL-6 with synovial IL-6 (sIL-6) and synovial C-reactive protein (sCRP). Study design: We performed a prospective study of 240 patients in whom serum IL-6 was determined before total hip (n = 124) or knee (n = 116) reoperations. The PJI diagnosis was based on the MSIS (Musculoskeletal Infection Society) criteria (2011). Receiver operating characteristic plots were constructed for IL-6, sIL-6, and sCRP. Results: PJI was diagnosed in 93 patients, and aseptic revision was diagnosed in 147 patients. The AUC (area under curve) for IL-6 was 0.938 (95% CI; 0.904–0.971). The optimal IL-6 cut-off value for PJI was 12.55 ng/L. Positive and negative likelihood ratios for IL-6 were 8.24 (95% CI; 4.79–14.17) and 0.15 (95% CI; 0.09–0.26), respectively. The optimal sIL-6 and sCRP cut-off values were 20,988 ng/L and 8.80 mg/L, respectively. Positive and negative likelihood ratios for sIL-6 were 40.000 (95% CI; 5.7–280.5) and 0.170 (95% CI; 0.07–0.417), respectively. Negative likelihood ratio for sCRP was 0.083 (95% CI; 0.022–0.314). Conclusions: The present study identified the cut-off values for serum/synovial IL-6 and synovial CRP for diagnostics of PJI at the site of THA and TKA and separately for each site. The diagnostic odds ratio for serum/synovial IL-6 and synovial CRP is very good. Simultaneous positivity of serum IL-6 either with synovial IL-6 or synovial CRP almost excludes false negative detection of PJI at the site of interest.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30211 - Orthopaedics
Návaznosti výsledku
Projekt
<a href="/cs/project/NV17-29680A" target="_blank" >NV17-29680A: Použití lipofosfonoxinů k prevenci a léčbě muskuloskeletárních infekcí: potenciální role nových antibakteriálních látek</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
PLoS One
ISSN
1932-6203
e-ISSN
—
Svazek periodika
13
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
16
Strana od-do
e0199226
Kód UT WoS článku
000435802500056
EID výsledku v databázi Scopus
2-s2.0-85048874593