Comparison of various methods of ischaemic cardioprotection on vitality of rat heart grafts
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F17%3A00067049" target="_blank" >RIV/00159816:_____/17:00067049 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/62157124:16170/17:43875748 RIV/62157124:16370/17:43875748
Výsledek na webu
<a href="http://dx.doi.org/10.2754/avb201786020199" target="_blank" >http://dx.doi.org/10.2754/avb201786020199</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2754/avb201786020199" target="_blank" >10.2754/avb201786020199</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of various methods of ischaemic cardioprotection on vitality of rat heart grafts
Popis výsledku v původním jazyce
The aim of the study was to compare 4 modes of ischaemic cardioprotection using continuous prograde autologous blood perfusion of the coronary artery in two hypothermic modes (group A, B) or conventional protection by cooled Hartmann solution (group C) or cooled saline (group D) without perfusion of the graft. Male Wistar rats (n = 24) were divided into four groups (A-D). In groups A (22-25 oC) and B (4-8 oC), blood perfusion rate was 10 ml/h and the graft was placed in a water bath. Groups C, D were initially rinsed with cold (4-8 oC) Hartmann solution (C) and cold saline solution (D), next the graft was placed in a water bath of cold (4-8 oC) Hartmann solution (C) or saline solution (D). The observed time was 30 min after the implemented perfusion (A, B) or initial rinsing (C, D). At 30 min, hearts of all the groups were perfused for 10 min with prograde-autologous arterialized blood at room temperature. At perfusion minute 10, blood was collected for biochemical analysis (sample 1). Sample 2 involved blood from a portable syringe infusion pumps (in parallel with sample 1). Pairwise test differences between samples 1 and 2 were signifcant in all the groups as regards creatine kinase and lactate dehydrogenase values, sampling 1 values being always higher, while cardiac troponin I concentrations were nonsignifcant in the same comparison. The heart rate during the fnal perfusion was identical in all the groups. Our study has demonstrated that all observed cardioprotection modes are useful for experimental heart grafting
Název v anglickém jazyce
Comparison of various methods of ischaemic cardioprotection on vitality of rat heart grafts
Popis výsledku anglicky
The aim of the study was to compare 4 modes of ischaemic cardioprotection using continuous prograde autologous blood perfusion of the coronary artery in two hypothermic modes (group A, B) or conventional protection by cooled Hartmann solution (group C) or cooled saline (group D) without perfusion of the graft. Male Wistar rats (n = 24) were divided into four groups (A-D). In groups A (22-25 oC) and B (4-8 oC), blood perfusion rate was 10 ml/h and the graft was placed in a water bath. Groups C, D were initially rinsed with cold (4-8 oC) Hartmann solution (C) and cold saline solution (D), next the graft was placed in a water bath of cold (4-8 oC) Hartmann solution (C) or saline solution (D). The observed time was 30 min after the implemented perfusion (A, B) or initial rinsing (C, D). At 30 min, hearts of all the groups were perfused for 10 min with prograde-autologous arterialized blood at room temperature. At perfusion minute 10, blood was collected for biochemical analysis (sample 1). Sample 2 involved blood from a portable syringe infusion pumps (in parallel with sample 1). Pairwise test differences between samples 1 and 2 were signifcant in all the groups as regards creatine kinase and lactate dehydrogenase values, sampling 1 values being always higher, while cardiac troponin I concentrations were nonsignifcant in the same comparison. The heart rate during the fnal perfusion was identical in all the groups. Our study has demonstrated that all observed cardioprotection modes are useful for experimental heart grafting
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
40301 - Veterinary science
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Veterinaria Brno
ISSN
0001-7213
e-ISSN
—
Svazek periodika
86
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
8
Strana od-do
199-206
Kód UT WoS článku
000405584800012
EID výsledku v databázi Scopus
—