Low leptin concentration may identify heart failure patients with central sleep apnea
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F18%3A00067034" target="_blank" >RIV/00159816:_____/18:00067034 - isvavai.cz</a>
Výsledek na webu
<a href="https://onlinelibrary.wiley.com/doi/full/10.1111/jsr.12574" target="_blank" >https://onlinelibrary.wiley.com/doi/full/10.1111/jsr.12574</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1111/jsr.12574" target="_blank" >10.1111/jsr.12574</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Low leptin concentration may identify heart failure patients with central sleep apnea
Popis výsledku v původním jazyce
Low leptin concentration has been shown to be associated with central sleep apnea in heart failure patients. We hypothesized that low leptin concentration predicts central sleep apnea. Consecutive ambulatory New York Heart Association (NYHA) classes I-IV heart failure patients were studied prospectively, including measurement of serum leptin, echocardiography and polysomnography. Sleep apnea was defined by type (central/mixed/obstructive) and by apnea-hypopnea index GREATER-THAN OR EQUAL TO5 by polysomnography. Subjects were divided into four groups by polysomnography: (1) central sleep apnea, (2) mixed apnea, (3) no apnea and (4) obstructive sleep apnea. Fifty-six subjects were included. Eighteen subjects were diagnosed with central sleep apnea, 15 with mixed apnea, 12 with obstructive apnea and 11 with no sleep apnea. Leptin concentration was significantly lower in central sleep apnea compared to obstructive apnea (8 +- 10.7 ng mL-1 versus 19.7 +- 14.7 ng mL-1 , P < 0.01) or no sleep apnea (8 +- 10.7 ng mL-1 versus 17.1 +- 8.4 ng mL-1 , P < 0.01). Logistic regression showed leptin to be associated independently with central sleep apnea [odds ratio (OR): 0.19; 95% confidence interval (CI): 0.06-0.62; area under the curve (AUC): 0.80, P < 0.01]. For the detection of central sleep apnea, a cut-off value for leptin concentration 5 ng mL-1 yielded a sensitivity of 50% and specificity of 89%. In conclusion, a low leptin concentration may have utility for the screening of heart failure patients for central sleep apnea.
Název v anglickém jazyce
Low leptin concentration may identify heart failure patients with central sleep apnea
Popis výsledku anglicky
Low leptin concentration has been shown to be associated with central sleep apnea in heart failure patients. We hypothesized that low leptin concentration predicts central sleep apnea. Consecutive ambulatory New York Heart Association (NYHA) classes I-IV heart failure patients were studied prospectively, including measurement of serum leptin, echocardiography and polysomnography. Sleep apnea was defined by type (central/mixed/obstructive) and by apnea-hypopnea index GREATER-THAN OR EQUAL TO5 by polysomnography. Subjects were divided into four groups by polysomnography: (1) central sleep apnea, (2) mixed apnea, (3) no apnea and (4) obstructive sleep apnea. Fifty-six subjects were included. Eighteen subjects were diagnosed with central sleep apnea, 15 with mixed apnea, 12 with obstructive apnea and 11 with no sleep apnea. Leptin concentration was significantly lower in central sleep apnea compared to obstructive apnea (8 +- 10.7 ng mL-1 versus 19.7 +- 14.7 ng mL-1 , P < 0.01) or no sleep apnea (8 +- 10.7 ng mL-1 versus 17.1 +- 8.4 ng mL-1 , P < 0.01). Logistic regression showed leptin to be associated independently with central sleep apnea [odds ratio (OR): 0.19; 95% confidence interval (CI): 0.06-0.62; area under the curve (AUC): 0.80, P < 0.01]. For the detection of central sleep apnea, a cut-off value for leptin concentration 5 ng mL-1 yielded a sensitivity of 50% and specificity of 89%. In conclusion, a low leptin concentration may have utility for the screening of heart failure patients for central sleep apnea.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30103 - Neurosciences (including psychophysiology)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Sleep Research
ISSN
0962-1105
e-ISSN
—
Svazek periodika
27
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
4
Strana od-do
240-243
Kód UT WoS článku
000426866500012
EID výsledku v databázi Scopus
—