Optimizing fast first pass complete reperfusion in acute ischemic stroke - the BADDASS approach (BAlloon guiDe with large bore Distal Access catheter with dual aspiration with Stent-retriever as Standard approach)
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F19%3A00072462" target="_blank" >RIV/00159816:_____/19:00072462 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/19:00111585
Výsledek na webu
<a href="https://www.tandfonline.com/doi/abs/10.1080/17434440.2019.1684263?journalCode=ierd20" target="_blank" >https://www.tandfonline.com/doi/abs/10.1080/17434440.2019.1684263?journalCode=ierd20</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1080/17434440.2019.1684263" target="_blank" >10.1080/17434440.2019.1684263</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Optimizing fast first pass complete reperfusion in acute ischemic stroke - the BADDASS approach (BAlloon guiDe with large bore Distal Access catheter with dual aspiration with Stent-retriever as Standard approach)
Popis výsledku v původním jazyce
Introduction: Endovascular therapy is the standard of care for acute ischemic stroke due to large vessel occlusions. The ultimate goal is to achieve fast first pass complete reperfusion, since delayed and/or incomplete reperfusion increases complication rates and costs and deteriorates patient outcome. Achieving optimal results can sometimes be challenging, particularly in patients with tortuous vessels. Several techniques have been described lately to optimize recanalization, including first line aspiration and various stent-retriever assisted techniques. In our experience, mechanical thrombectomy with a BAlloon guide catheter, large bore Distal access catheter, Dual Aspiration and Stent-retriever as Standard approach (BADDASS) is the most efficient technique to succeed, since it combines the advantages of stent-retrievers and distal aspiration. Areas covered: The purpose of this review is to enable neurointerventionalists to achieve fast first pass complete reperfusion by outlining the BADDASS approach step-by-step and sharing additional tips for navigating through challenging internal carotid artery segments. Expert opinion: In our experience, the BADDASS approach is the safest and most effective way to achieve fast first pass complete reperfusion.
Název v anglickém jazyce
Optimizing fast first pass complete reperfusion in acute ischemic stroke - the BADDASS approach (BAlloon guiDe with large bore Distal Access catheter with dual aspiration with Stent-retriever as Standard approach)
Popis výsledku anglicky
Introduction: Endovascular therapy is the standard of care for acute ischemic stroke due to large vessel occlusions. The ultimate goal is to achieve fast first pass complete reperfusion, since delayed and/or incomplete reperfusion increases complication rates and costs and deteriorates patient outcome. Achieving optimal results can sometimes be challenging, particularly in patients with tortuous vessels. Several techniques have been described lately to optimize recanalization, including first line aspiration and various stent-retriever assisted techniques. In our experience, mechanical thrombectomy with a BAlloon guide catheter, large bore Distal access catheter, Dual Aspiration and Stent-retriever as Standard approach (BADDASS) is the most efficient technique to succeed, since it combines the advantages of stent-retrievers and distal aspiration. Areas covered: The purpose of this review is to enable neurointerventionalists to achieve fast first pass complete reperfusion by outlining the BADDASS approach step-by-step and sharing additional tips for navigating through challenging internal carotid artery segments. Expert opinion: In our experience, the BADDASS approach is the safest and most effective way to achieve fast first pass complete reperfusion.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20602 - Medical laboratory technology (including laboratory samples analysis; diagnostic technologies) (Biomaterials to be 2.9 [physical characteristics of living material as related to medical implants, devices, sensors])
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Expert Review of Medical Devices
ISSN
1743-4440
e-ISSN
—
Svazek periodika
16
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
9
Strana od-do
955-963
Kód UT WoS článku
000493533300001
EID výsledku v databázi Scopus
—