Mitigation of Exercise Oscillatory Ventilation Score by Cardiac Resynchronization Therapy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F20%3A00073517" target="_blank" >RIV/00159816:_____/20:00073517 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/20:00116819
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/abs/pii/S1071916419307547?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/abs/pii/S1071916419307547?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.cardfail.2020.03.006" target="_blank" >10.1016/j.cardfail.2020.03.006</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Mitigation of Exercise Oscillatory Ventilation Score by Cardiac Resynchronization Therapy
Popis výsledku v původním jazyce
Background: Exercise oscillatory ventilation (EOV) is a consequence of ventilatory control system instability and is commonly observed in patients with advanced heart failure (HF); it is associated with adverse prognosis. The goal of this study was to evaluate the effects of cardiac resynchronization therapy (CRT) on oscillatory ventilation as quantified by a proposed EOV score. Methods and Results: Consecutive patients with HF (N = 35) who underwent clinically indicated CRT, cardiopulmonary exercise testing and carbon dioxide (CO2) chemosensitivity by rebreathe before and 4-6 months after CRT were included in this post hoc analysis. With CRT, EOV scores improved in 22 patients (63%). In these patients, left ventricular ejection fraction, left atrial volume, brain natriuretic peptide concentration, and CO2 chemosensitivity significantly improved after CRT (P < 0.05). Furthermore, minute ventilation per unit CO2 production significantly decreased, and end-tidal CO2 increased at rest and at peak exercise post-CRT. Multiple regression analysis showed only the change of CO2 chemosensitivity to be significantly associated with the improvement of the EOV score (b = 0.64; F = 11.3; P = 0.004). In the group without EOV score improvement (n = 13), though left ventricular ejection fraction significantly increased with CRT (P = 0.015), no significant changes in ventilation or gas exchange were observed. Conclusion: The EOV score was mitigated by CRT and was associated with decreased CO2 chemosensitivity.
Název v anglickém jazyce
Mitigation of Exercise Oscillatory Ventilation Score by Cardiac Resynchronization Therapy
Popis výsledku anglicky
Background: Exercise oscillatory ventilation (EOV) is a consequence of ventilatory control system instability and is commonly observed in patients with advanced heart failure (HF); it is associated with adverse prognosis. The goal of this study was to evaluate the effects of cardiac resynchronization therapy (CRT) on oscillatory ventilation as quantified by a proposed EOV score. Methods and Results: Consecutive patients with HF (N = 35) who underwent clinically indicated CRT, cardiopulmonary exercise testing and carbon dioxide (CO2) chemosensitivity by rebreathe before and 4-6 months after CRT were included in this post hoc analysis. With CRT, EOV scores improved in 22 patients (63%). In these patients, left ventricular ejection fraction, left atrial volume, brain natriuretic peptide concentration, and CO2 chemosensitivity significantly improved after CRT (P < 0.05). Furthermore, minute ventilation per unit CO2 production significantly decreased, and end-tidal CO2 increased at rest and at peak exercise post-CRT. Multiple regression analysis showed only the change of CO2 chemosensitivity to be significantly associated with the improvement of the EOV score (b = 0.64; F = 11.3; P = 0.004). In the group without EOV score improvement (n = 13), though left ventricular ejection fraction significantly increased with CRT (P = 0.015), no significant changes in ventilation or gas exchange were observed. Conclusion: The EOV score was mitigated by CRT and was associated with decreased CO2 chemosensitivity.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Cardiac Failure
ISSN
1071-9164
e-ISSN
—
Svazek periodika
26
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
832-840
Kód UT WoS článku
000579894900005
EID výsledku v databázi Scopus
—