Real-Time Quality Assessment of Long-Term ECG Signals Recorded by Wearables in Free-Living Conditions
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F20%3A00073519" target="_blank" >RIV/00159816:_____/20:00073519 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26220/20:PU137371
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/8970507" target="_blank" >https://ieeexplore.ieee.org/document/8970507</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/TBME.2020.2969719" target="_blank" >10.1109/TBME.2020.2969719</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Real-Time Quality Assessment of Long-Term ECG Signals Recorded by Wearables in Free-Living Conditions
Popis výsledku v původním jazyce
Objective: Nowadays, methods for ECG quality assessment are mostly designed to binary distinguish between good/bad quality of the whole signal. Such classification is not suitable to long-term data collected by wearable devices. In this paper, a novel approach to estimate long-term ECG signal quality is proposed. Methods: The real-time quality estimation is performed in a local time window by calculation of continuous signal-to-noise ratio (SNR) curve. The layout of the data quality segments is determined by analysis of SNR waveform. It is distinguished between three levels of ECG signal quality: signal suitable for full wave ECG analysis, signal suitable only for QRS detection, and signal unsuitable for further processing. Results: The SNR limits for reliable QRS detection and full ECG waveform analysis are 5 and 18 dB respectively. The method was developed and tested using synthetic data and validated on real data from wearable device. Conclusion: The proposed solution is a robust, accurate and computationally efficient algorithm for annotation of ECG signal quality that will facilitate the subsequent tailored analysis of ECG signals recorded in free-living conditions. Significance: The field of long-term ECG signals self-monitoring by wearable devices is swiftly developing. The analysis of massive amount of collected data is time consuming. It is advantageous to characterize data quality in advance and thereby limit consequent analysis to useable signals.
Název v anglickém jazyce
Real-Time Quality Assessment of Long-Term ECG Signals Recorded by Wearables in Free-Living Conditions
Popis výsledku anglicky
Objective: Nowadays, methods for ECG quality assessment are mostly designed to binary distinguish between good/bad quality of the whole signal. Such classification is not suitable to long-term data collected by wearable devices. In this paper, a novel approach to estimate long-term ECG signal quality is proposed. Methods: The real-time quality estimation is performed in a local time window by calculation of continuous signal-to-noise ratio (SNR) curve. The layout of the data quality segments is determined by analysis of SNR waveform. It is distinguished between three levels of ECG signal quality: signal suitable for full wave ECG analysis, signal suitable only for QRS detection, and signal unsuitable for further processing. Results: The SNR limits for reliable QRS detection and full ECG waveform analysis are 5 and 18 dB respectively. The method was developed and tested using synthetic data and validated on real data from wearable device. Conclusion: The proposed solution is a robust, accurate and computationally efficient algorithm for annotation of ECG signal quality that will facilitate the subsequent tailored analysis of ECG signals recorded in free-living conditions. Significance: The field of long-term ECG signals self-monitoring by wearable devices is swiftly developing. The analysis of massive amount of collected data is time consuming. It is advantageous to characterize data quality in advance and thereby limit consequent analysis to useable signals.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20602 - Medical laboratory technology (including laboratory samples analysis; diagnostic technologies) (Biomaterials to be 2.9 [physical characteristics of living material as related to medical implants, devices, sensors])
Návaznosti výsledku
Projekt
<a href="/cs/project/LQ1605" target="_blank" >LQ1605: Translační medicína</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
IEEE Transactions on Biomedical Engineering
ISSN
0018-9294
e-ISSN
—
Svazek periodika
67
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
14
Strana od-do
2721-2734
Kód UT WoS článku
000571741600002
EID výsledku v databázi Scopus
—