Time-related factors predicting a positive response to cardiac resynchronisation therapy in patients with heart failure
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F23%3A00079654" target="_blank" >RIV/00159816:_____/23:00079654 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.nature.com/articles/s41598-023-35174-9" target="_blank" >https://www.nature.com/articles/s41598-023-35174-9</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1038/s41598-023-35174-9" target="_blank" >10.1038/s41598-023-35174-9</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Time-related factors predicting a positive response to cardiac resynchronisation therapy in patients with heart failure
Popis výsledku v původním jazyce
This study aimed to identify time parameters predicting favourable CRT response. A total of 38 patients with ischemic cardiomyopathy, qualified for CRT implantation, were enrolled in the study. A 15% reduction in indexed end-systolic volume after 6 months was a criterion for a positive response to CRT. We evaluated QRS duration, measured from a standard ECG before and after CRT implantation and obtained from mapping with NOGA XP system (AEMM); and the delay, measured with the implanted device algorithm (DCD) and its change after 6 months (Delta DCD); and selected delay parameters between the left and right ventricles based on AEMM data. A total of 24 patients presented with a positive response to CRT versus 9 non-responders. After CRT implantation, we observed differences between responders and non-responders group in the reduction of QRS duration (31 ms vs. 16 ms), duration of paced QRS (123 ms vs. 142 ms), and the change of Delta DCDMaximum (4.9 ms vs. 0.44 ms) and Delta DCDMean (7.7 ms vs. 0.9 ms). The difference in selected parameters obtained during AEMM in both groups was related to interventricular delay (40.3 ms vs. 18.6 ms). Concerning local activation time and left ventricular activation time, we analysed the delays in individual left ventricular segments. Predominant activation delay of the posterior wall middle segment was associated with a better response to CRT. Some AEMM parameters, paced QRS time of less than 120 ms and reduction of QRS duration greater than 20 ms predict the response to CRT. Delta DCD is associated with favourable electrical and structural remodelling.: SUM No. KNW/0022/KB1/17/15.
Název v anglickém jazyce
Time-related factors predicting a positive response to cardiac resynchronisation therapy in patients with heart failure
Popis výsledku anglicky
This study aimed to identify time parameters predicting favourable CRT response. A total of 38 patients with ischemic cardiomyopathy, qualified for CRT implantation, were enrolled in the study. A 15% reduction in indexed end-systolic volume after 6 months was a criterion for a positive response to CRT. We evaluated QRS duration, measured from a standard ECG before and after CRT implantation and obtained from mapping with NOGA XP system (AEMM); and the delay, measured with the implanted device algorithm (DCD) and its change after 6 months (Delta DCD); and selected delay parameters between the left and right ventricles based on AEMM data. A total of 24 patients presented with a positive response to CRT versus 9 non-responders. After CRT implantation, we observed differences between responders and non-responders group in the reduction of QRS duration (31 ms vs. 16 ms), duration of paced QRS (123 ms vs. 142 ms), and the change of Delta DCDMaximum (4.9 ms vs. 0.44 ms) and Delta DCDMean (7.7 ms vs. 0.9 ms). The difference in selected parameters obtained during AEMM in both groups was related to interventricular delay (40.3 ms vs. 18.6 ms). Concerning local activation time and left ventricular activation time, we analysed the delays in individual left ventricular segments. Predominant activation delay of the posterior wall middle segment was associated with a better response to CRT. Some AEMM parameters, paced QRS time of less than 120 ms and reduction of QRS duration greater than 20 ms predict the response to CRT. Delta DCD is associated with favourable electrical and structural remodelling.: SUM No. KNW/0022/KB1/17/15.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Scientific Reports
ISSN
2045-2322
e-ISSN
2045-2322
Svazek periodika
13
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
9
Strana od-do
8524
Kód UT WoS článku
001001070500061
EID výsledku v databázi Scopus
—