Comparison of Speckle Tracking Echocardiography During Different Pacing Modalities for Cardiac Resynchronization Therapy Response Prediction
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F22%3A10448758" target="_blank" >RIV/00216208:11110/22:10448758 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=t0IKeOCBUC" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=t0IKeOCBUC</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.17925/HI.2022.16.1.64" target="_blank" >10.17925/HI.2022.16.1.64</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of Speckle Tracking Echocardiography During Different Pacing Modalities for Cardiac Resynchronization Therapy Response Prediction
Popis výsledku v původním jazyce
Background: The aim of this study was to evaluate left ventricular mechanical activation pattern by speckle tracking echocardiography (STE) as a predictor of response to cardiac resynchronization therapy (CRT) in patients with heart failure. Methods: Echocardiography was performed during no pacing, right ventricular pacing (RVP), biventricular pacing (BVP) and multipolar pacing (MPP) immediately after CRT implantation in 16 patients at a single centre. Seven patients were diagnosed as responders and 9 patients as non-responders after 6 months of standard CRT pacing. All had adequate short axis views, and 1 CRT responder and 2 CRT non-responders had limited longitudinal views. Results: Longitudinal and circumferential global strain (GS) and global strain rate (GSR) or their change analysis, did not yield any CRT response prediction. However, the longitudinal BVP/RVP GS ratio was significantly higher in the responder group (1.32 +/- 0.2%, 2.0 +/- 0.4% and 1.9 +/- 0.4%), compared with the non- responder group (1.06 +/- 0.2%, 1.1 +/- 0.4% and 1.2 +/- 0.4%) in the apical two-chamber, APLAX and four-chamber views, respectively. Similarly, the longitudinal BVP/RVP GSR at active systolic phase (GSRs) was significantly higher in the responder group (1.9 +/- 0.9% and 1.7 +/- 0.4%) compared with the non-responder group ( 1.0 +/- 0.4% and 1.1 +/- 0.2%) in the apical APLAX and four-chamber views, respectively. Measurements of the strain delay index showed predictive power regarding CRT response in non-paced patients. Conclusion: Post implantation, longitudinal BVP/RVP GS and GSRs ratios of 1.4% and above may be useful as a CRT response prediction tool. Furthermore, our findings support the usefulness of strain delay index prior to CRT implantation in non-paced patients.
Název v anglickém jazyce
Comparison of Speckle Tracking Echocardiography During Different Pacing Modalities for Cardiac Resynchronization Therapy Response Prediction
Popis výsledku anglicky
Background: The aim of this study was to evaluate left ventricular mechanical activation pattern by speckle tracking echocardiography (STE) as a predictor of response to cardiac resynchronization therapy (CRT) in patients with heart failure. Methods: Echocardiography was performed during no pacing, right ventricular pacing (RVP), biventricular pacing (BVP) and multipolar pacing (MPP) immediately after CRT implantation in 16 patients at a single centre. Seven patients were diagnosed as responders and 9 patients as non-responders after 6 months of standard CRT pacing. All had adequate short axis views, and 1 CRT responder and 2 CRT non-responders had limited longitudinal views. Results: Longitudinal and circumferential global strain (GS) and global strain rate (GSR) or their change analysis, did not yield any CRT response prediction. However, the longitudinal BVP/RVP GS ratio was significantly higher in the responder group (1.32 +/- 0.2%, 2.0 +/- 0.4% and 1.9 +/- 0.4%), compared with the non- responder group (1.06 +/- 0.2%, 1.1 +/- 0.4% and 1.2 +/- 0.4%) in the apical two-chamber, APLAX and four-chamber views, respectively. Similarly, the longitudinal BVP/RVP GSR at active systolic phase (GSRs) was significantly higher in the responder group (1.9 +/- 0.9% and 1.7 +/- 0.4%) compared with the non-responder group ( 1.0 +/- 0.4% and 1.1 +/- 0.2%) in the apical APLAX and four-chamber views, respectively. Measurements of the strain delay index showed predictive power regarding CRT response in non-paced patients. Conclusion: Post implantation, longitudinal BVP/RVP GS and GSRs ratios of 1.4% and above may be useful as a CRT response prediction tool. Furthermore, our findings support the usefulness of strain delay index prior to CRT implantation in non-paced patients.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Heart International
ISSN
2036-2579
e-ISSN
—
Svazek periodika
16
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
IT - Italská republika
Počet stran výsledku
7
Strana od-do
64-70
Kód UT WoS článku
000864832900009
EID výsledku v databázi Scopus
2-s2.0-85133921427