Standardisation of 54Mn and 65Zn using a software coincidence counting system
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F06%3A%230000287" target="_blank" >RIV/00177016:_____/06:#0000287 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Standardisation of 54Mn and 65Zn using a software coincidence counting system
Popis výsledku v původním jazyce
The activities of 54Mn and 65Zn have been determined by 4pi(PC)gamma coincidence counting, with efficiency variation performed by the conventional method of altering the self-absorption in the sources as well as by the computer discrimination method. Thestandardisation of 65Zn presents some complications requiring optimisation of the gamma-ray energy window settings to achieve a linear efficiency-extrapolation curve. Determination of these optimal settings by the conventional coincidence method is a tedious task. These difficulties have been reduced by the utilisation of a software coincidence counting system that records time and amplitude information of individual pulses from coincidence measurements, where the coincidence parameters are set after the data collection process has completed, facilitating multiple data evaluations on a single data set.
Název v anglickém jazyce
Standardisation of 54Mn and 65Zn using a software coincidence counting system
Popis výsledku anglicky
The activities of 54Mn and 65Zn have been determined by 4pi(PC)gamma coincidence counting, with efficiency variation performed by the conventional method of altering the self-absorption in the sources as well as by the computer discrimination method. Thestandardisation of 65Zn presents some complications requiring optimisation of the gamma-ray energy window settings to achieve a linear efficiency-extrapolation curve. Determination of these optimal settings by the conventional coincidence method is a tedious task. These difficulties have been reduced by the utilisation of a software coincidence counting system that records time and amplitude information of individual pulses from coincidence measurements, where the coincidence parameters are set after the data collection process has completed, facilitating multiple data evaluations on a single data set.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
R - Projekt Ramcoveho programu EK
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Radiation and Isotopes
ISSN
0969-8043
e-ISSN
—
Svazek periodika
64
Číslo periodika v rámci svazku
10-11
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
5
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—