Activities of the radionuclides 124Sb and 152Eu were determined by the efficiency extrapolation method applied to 4pi(PC)-gamma coincidence counting. The 124Sb sources were prepared from a solution with the chemical form of 50 microg.g-1 SbCl3 in 2 M HCl. To inhibit the volatility of antimony chlorides, the sources were slowly dried in a H2S atmosphere with relative humidity of 76% for about 48 hours. This procedure increased the beta detection efficiency up to 0.98, which simplified the standardisation. In the 152Eu standardisation, the optimal gamma- ray energy window setting to achieve a linear dependency and the correct slope of the extrapolation curve were derived by means of software coincidence counting system using offline evaluation of data with different coincidence parameter settings. The results obtained by the software coincidence counting system were compared with those obtained by the conventional coincidence method.
Název v anglickém jazyce
Standardisation of 124Sb and 152Eu using a software coincidence counting system
Popis výsledku anglicky
Activities of the radionuclides 124Sb and 152Eu were determined by the efficiency extrapolation method applied to 4pi(PC)-gamma coincidence counting. The 124Sb sources were prepared from a solution with the chemical form of 50 microg.g-1 SbCl3 in 2 M HCl. To inhibit the volatility of antimony chlorides, the sources were slowly dried in a H2S atmosphere with relative humidity of 76% for about 48 hours. This procedure increased the beta detection efficiency up to 0.98, which simplified the standardisation. In the 152Eu standardisation, the optimal gamma- ray energy window setting to achieve a linear dependency and the correct slope of the extrapolation curve were derived by means of software coincidence counting system using offline evaluation of data with different coincidence parameter settings. The results obtained by the software coincidence counting system were compared with those obtained by the conventional coincidence method.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
R - Projekt Ramcoveho programu EK
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Radiation and Isotopes
ISSN
0969-8043
e-ISSN
—
Svazek periodika
68
Číslo periodika v rámci svazku
7-8
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
5
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—