The activity of electron capture radionuclides is usually determined by 4pi(PC)-gamma coincidence counting. The corrections necessary for the final activity value calculation are obtained by an extrapolation method. Variation of the proportional counter(PC) detection efficiency can be achieved through different methods, e.g. by changing the self-absorption of the source using absorbing foils or by adding carrier. Another possibility is a ?wet? extrapolation method, which utilises an absorption change during the drying of a water droplet added onto the source surface. In this paper, slopes of extrapolation curves and resulting activity values obtained by different methods are compared for several radionuclides (54Mn, 139Ce, 88Y, 57Co). In some cases adigital coincidence system was used for the analysis of measured data. The ?wet? extrapolation, due to its very simple procedure, seems to be convenient for routine measurement and its accuracy is similar to the other methods.
Název v anglickém jazyce
Application of ?wet? extrapolation method for activity standardisation of electron capture radionuclides
Popis výsledku anglicky
The activity of electron capture radionuclides is usually determined by 4pi(PC)-gamma coincidence counting. The corrections necessary for the final activity value calculation are obtained by an extrapolation method. Variation of the proportional counter(PC) detection efficiency can be achieved through different methods, e.g. by changing the self-absorption of the source using absorbing foils or by adding carrier. Another possibility is a ?wet? extrapolation method, which utilises an absorption change during the drying of a water droplet added onto the source surface. In this paper, slopes of extrapolation curves and resulting activity values obtained by different methods are compared for several radionuclides (54Mn, 139Ce, 88Y, 57Co). In some cases adigital coincidence system was used for the analysis of measured data. The ?wet? extrapolation, due to its very simple procedure, seems to be convenient for routine measurement and its accuracy is similar to the other methods.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
R - Projekt Ramcoveho programu EK
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Radiation and Isotopes
ISSN
0969-8043
e-ISSN
—
Svazek periodika
66
Číslo periodika v rámci svazku
6-7
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—