Report on EUROMET.RI(I)-K1 and EUROMET.RI(I)-K4 (EUROMET project no. 813): Comparison of air kerma and absorbed dose to water measurements of 60Co radiation beams for radiotherapy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F10%3A%230000870" target="_blank" >RIV/00177016:_____/10:#0000870 - isvavai.cz</a>
Výsledek na webu
<a href="http://iopscience.iop.org/0026-1394/47/1A/06012/" target="_blank" >http://iopscience.iop.org/0026-1394/47/1A/06012/</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/0026-1394/47/1A/06012" target="_blank" >10.1088/0026-1394/47/1A/06012</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Report on EUROMET.RI(I)-K1 and EUROMET.RI(I)-K4 (EUROMET project no. 813): Comparison of air kerma and absorbed dose to water measurements of 60Co radiation beams for radiotherapy
Popis výsledku v původním jazyce
The results of an unprecedented international effort involving 26 countries are reported. The EUROMET.RI(I)-K1 and EUROMET.RI(I)-K4 key comparisons were conducted with the goal of supporting the relevant calibration and measurement capabilities (CMC) planned for publication by the participant laboratories. The measured quantities were the air kerma (Kair) and the absorbed dose to water (Dw) in 60Co radiotherapy beams. The comparison was conducted by the pilot laboratory MKEH (Hungary), in a star-shapedarrangement from January 2005 to December 2008. The calibration coefficients of four transfer ionization chambers were measured using two electrometers. The largest deviation between any two calibration coefficients for the four chambers in terms of airkerma and absorbed dose to water was 2.7% and 3.3% respectively. An analysis of the participant uncertainty budgets enabled the calculation of degrees of equivalence (DoE), in terms of the deviations of the results and their associated un
Název v anglickém jazyce
Report on EUROMET.RI(I)-K1 and EUROMET.RI(I)-K4 (EUROMET project no. 813): Comparison of air kerma and absorbed dose to water measurements of 60Co radiation beams for radiotherapy
Popis výsledku anglicky
The results of an unprecedented international effort involving 26 countries are reported. The EUROMET.RI(I)-K1 and EUROMET.RI(I)-K4 key comparisons were conducted with the goal of supporting the relevant calibration and measurement capabilities (CMC) planned for publication by the participant laboratories. The measured quantities were the air kerma (Kair) and the absorbed dose to water (Dw) in 60Co radiotherapy beams. The comparison was conducted by the pilot laboratory MKEH (Hungary), in a star-shapedarrangement from January 2005 to December 2008. The calibration coefficients of four transfer ionization chambers were measured using two electrometers. The largest deviation between any two calibration coefficients for the four chambers in terms of airkerma and absorbed dose to water was 2.7% and 3.3% respectively. An analysis of the participant uncertainty budgets enabled the calculation of degrees of equivalence (DoE), in terms of the deviations of the results and their associated un
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Metrologia
ISSN
0026-1394
e-ISSN
—
Svazek periodika
47
Číslo periodika v rámci svazku
Issue 1A
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
100