Influenza in seasons 2009-2013 in the Faculty Hospital Hradec Kralove, East Bohemia
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F14%3A10284343" target="_blank" >RIV/00179906:_____/14:10284343 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60162694:G44__/14:43875177
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influenza in seasons 2009-2013 in the Faculty Hospital Hradec Kralove, East Bohemia
Popis výsledku v původním jazyce
Purpose: The evaluation of four post-pandemic influenza seasons 2009-2013 in the Faculty hospital Hradec Králové and comparison of used rapid antigen tests (RATs) with real time RT-PCR. Material and methods: Between November 2009 and June 2013 were examined 3845 samples from patients with respiratory tract infections by RATs (Influenza A/B 2 Panel Test (GECKO(R) Pharma, Germany), Rapid VIDITEST Influenza A+B Card (VIDIA(R), Czech Republic) and BinaxNOW Influenza A&B Test (ALERE(R), USA) or real time RT-PCR (RTR InfA/H1N1 Detection Set (Roche(R)), RealStar(R) Influenza S and T RT-PCR Kit 3.0 (Altona (R), Germany). Results:A totally 1059 samples were examined simultaneously by RAT and real time RT-PCR. The overall sensitivity and specificity of RATs compared with real time RT-PCR were 32.2% and 98.1% for influenza A and 17.6% and 99.4% for influenza B. Higher sensitivity of RATs were in children (66.6%) compared with adults (14.3 - 40.0 %). In the first three post-pandemic seasons were c
Název v anglickém jazyce
Influenza in seasons 2009-2013 in the Faculty Hospital Hradec Kralove, East Bohemia
Popis výsledku anglicky
Purpose: The evaluation of four post-pandemic influenza seasons 2009-2013 in the Faculty hospital Hradec Králové and comparison of used rapid antigen tests (RATs) with real time RT-PCR. Material and methods: Between November 2009 and June 2013 were examined 3845 samples from patients with respiratory tract infections by RATs (Influenza A/B 2 Panel Test (GECKO(R) Pharma, Germany), Rapid VIDITEST Influenza A+B Card (VIDIA(R), Czech Republic) and BinaxNOW Influenza A&B Test (ALERE(R), USA) or real time RT-PCR (RTR InfA/H1N1 Detection Set (Roche(R)), RealStar(R) Influenza S and T RT-PCR Kit 3.0 (Altona (R), Germany). Results:A totally 1059 samples were examined simultaneously by RAT and real time RT-PCR. The overall sensitivity and specificity of RATs compared with real time RT-PCR were 32.2% and 98.1% for influenza A and 17.6% and 99.4% for influenza B. Higher sensitivity of RATs were in children (66.6%) compared with adults (14.3 - 40.0 %). In the first three post-pandemic seasons were c
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
EE - Mikrobiologie, virologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Epidemiologie, Mikrobiologie, Imunologie
ISSN
1210-7913
e-ISSN
—
Svazek periodika
63
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
7
Strana od-do
10-16
Kód UT WoS článku
000343635100003
EID výsledku v databázi Scopus
—