Speed and quality of interbody fusion in porous bioceramic Al2O3 and polyetheretherketone cages for anterior cervical discectomy and fusion: a comparative study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F23%3A10464731" target="_blank" >RIV/00179906:_____/23:10464731 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11150/23:10464731
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=uhfwMkqWzH" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=uhfwMkqWzH</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1186/s13018-023-03625-8" target="_blank" >10.1186/s13018-023-03625-8</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Speed and quality of interbody fusion in porous bioceramic Al2O3 and polyetheretherketone cages for anterior cervical discectomy and fusion: a comparative study
Popis výsledku v původním jazyce
BackgroundThe objective of this prospective randomized monocentric study is to compare the speed and quality of interbody fusion of implanted porous Al2O3 (aluminium oxide) cages with PEEK (polyetheretherketone) cages in ACDF (anterior cervical discectomy and fusion).Materials and methodsA total of 111 patients were enrolled in the study, which was carried out between 2015 and 2021. The 18-month follow-up (FU) was completed in 68 patients with an Al2O3 cage and 35 patients with a PEEK cage in one-level ACDF. Initially, the first evidence (initialization) of fusion was evaluated on computed tomography. Subsequently, interbody fusion was evaluated according to the fusion quality scale, fusion rate and incidence of subsidence.ResultsSigns of incipient fusion at 3 months were detected in 22% of cases with the Al2O3 cage and 37.1% with the PEEK cage. At 12-month FU, the fusion rate was 88.2% for Al2O3 and 97.1% for PEEK cages, and at the final FU at 18 months, 92.6% and 100%, respectively. The incidence of subsidence was observed to be 11.8% and 22.9% of cases with Al2O3 and PEEK cages, respectively.ConclusionsPorous Al2O3 cages demonstrated a lower speed and quality of fusion in comparison with PEEK cages. However, the fusion rate of Al2O3 cages was within the range of published results for various cages. The incidence of subsidence of Al2O3 cages was lower compared to published results. We consider the porous Al2O3 cage as safe for a stand-alone disc replacement in ACDF.
Název v anglickém jazyce
Speed and quality of interbody fusion in porous bioceramic Al2O3 and polyetheretherketone cages for anterior cervical discectomy and fusion: a comparative study
Popis výsledku anglicky
BackgroundThe objective of this prospective randomized monocentric study is to compare the speed and quality of interbody fusion of implanted porous Al2O3 (aluminium oxide) cages with PEEK (polyetheretherketone) cages in ACDF (anterior cervical discectomy and fusion).Materials and methodsA total of 111 patients were enrolled in the study, which was carried out between 2015 and 2021. The 18-month follow-up (FU) was completed in 68 patients with an Al2O3 cage and 35 patients with a PEEK cage in one-level ACDF. Initially, the first evidence (initialization) of fusion was evaluated on computed tomography. Subsequently, interbody fusion was evaluated according to the fusion quality scale, fusion rate and incidence of subsidence.ResultsSigns of incipient fusion at 3 months were detected in 22% of cases with the Al2O3 cage and 37.1% with the PEEK cage. At 12-month FU, the fusion rate was 88.2% for Al2O3 and 97.1% for PEEK cages, and at the final FU at 18 months, 92.6% and 100%, respectively. The incidence of subsidence was observed to be 11.8% and 22.9% of cases with Al2O3 and PEEK cages, respectively.ConclusionsPorous Al2O3 cages demonstrated a lower speed and quality of fusion in comparison with PEEK cages. However, the fusion rate of Al2O3 cages was within the range of published results for various cages. The incidence of subsidence of Al2O3 cages was lower compared to published results. We consider the porous Al2O3 cage as safe for a stand-alone disc replacement in ACDF.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30103 - Neurosciences (including psychophysiology)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Orthopaedic Surgery and Research
ISSN
1749-799X
e-ISSN
—
Svazek periodika
18
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
165
Kód UT WoS článku
000943497100002
EID výsledku v databázi Scopus
2-s2.0-85149550252