In vivo visualization of cells labeled with superparamagnetic iron oxides by a sub-millisecond gradient echo sequence
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F14%3A10192018" target="_blank" >RIV/00216208:11110/14:10192018 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00023001:_____/14:00059036
Výsledek na webu
<a href="http://link.springer.com/article/10.1007%2Fs10334-013-0422-3" target="_blank" >http://link.springer.com/article/10.1007%2Fs10334-013-0422-3</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10334-013-0422-3" target="_blank" >10.1007/s10334-013-0422-3</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
In vivo visualization of cells labeled with superparamagnetic iron oxides by a sub-millisecond gradient echo sequence
Popis výsledku v původním jazyce
In vivo magnetic resonance imaging (MRI) of iron-labeled pancreatic islets (PIs) transplanted into the liver is still challenging in humans. The aim of this study was to develop and evaluate a double contrast method for the detection of PIs labeled withsuperparamagnetic iron oxide (SPIO) nanoparticles. Materials and methods: A double-echo three-dimensional (3D) spoiled gradient echo sequence was adapted to yield a sub-millisecond first echo time using variable echo times and highly asymmetric Cartesianreadout. Positive contrast was achieved by conventional and relative image subtraction. Experiments for cell detection efficiency were performed in vitro on gelatin phantoms, in vivo on a Lewis rat and on a patient 6 months after PI transplantation. Results: It was demonstrated that the proposed method can be used for the detection of transplanted PIs with positive contrast in vitro and in vivo. For all experiments, relative subtraction yielded comparable and in some cases better contra
Název v anglickém jazyce
In vivo visualization of cells labeled with superparamagnetic iron oxides by a sub-millisecond gradient echo sequence
Popis výsledku anglicky
In vivo magnetic resonance imaging (MRI) of iron-labeled pancreatic islets (PIs) transplanted into the liver is still challenging in humans. The aim of this study was to develop and evaluate a double contrast method for the detection of PIs labeled withsuperparamagnetic iron oxide (SPIO) nanoparticles. Materials and methods: A double-echo three-dimensional (3D) spoiled gradient echo sequence was adapted to yield a sub-millisecond first echo time using variable echo times and highly asymmetric Cartesianreadout. Positive contrast was achieved by conventional and relative image subtraction. Experiments for cell detection efficiency were performed in vitro on gelatin phantoms, in vivo on a Lewis rat and on a patient 6 months after PI transplantation. Results: It was demonstrated that the proposed method can be used for the detection of transplanted PIs with positive contrast in vitro and in vivo. For all experiments, relative subtraction yielded comparable and in some cases better contra
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FP - Ostatní lékařské obory
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NT13099" target="_blank" >NT13099: Optimalizace kultivačních podmínek izolovaných Langerhnasových ostrůvků určených k transplantaci</a><br>
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Magnetic Resonance Materials in Physics, Biology, and Medicine
ISSN
0968-5243
e-ISSN
—
Svazek periodika
27
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
329-337
Kód UT WoS článku
000339833300006
EID výsledku v databázi Scopus
—