Rapid determination of branched chain amino acids in human blood plasma by pressure assisted capillary electrophoresis with contactless conductivity detection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F15%3A43909342" target="_blank" >RIV/00216208:11120/15:43909342 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064173:_____/15:#0000489
Výsledek na webu
<a href="http://dx.doi.org/10.1002/elps.201400585" target="_blank" >http://dx.doi.org/10.1002/elps.201400585</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elps.201400585" target="_blank" >10.1002/elps.201400585</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Rapid determination of branched chain amino acids in human blood plasma by pressure assisted capillary electrophoresis with contactless conductivity detection
Popis výsledku v původním jazyce
A capillary electrophoresis (CE) method with contactless conductivity detection has been developed for the clinical determination of the branched chain amino acids (BCAAs) valine, isoleucine, and leucine in human blood plasma. The CE separation was performed in an optimized background electrolyte with composition 3.2 M acetic acid in 20% v/v methanol, pH 2.0. The achieved separation time was 125 s when using a capillary with an effective length of 14.7 cm, electric field intensity of 0.96 kV/cm and simultaneous application of a hydrodynamic pressure of 50 mbar. The separation efficiency in blood plasma equalled 461 000 theoretical plates/m for valine and isoleucine, and 455 000 theoretical plates/m for leucine; the detection limits are equal to 0.4 ?Mfor all three amino acids. The relative standard deviation values for repeatability of the migration time equalled 0.1% for measurements during a single day and 0.3% for measurements on different days; the relative standard deviation valu
Název v anglickém jazyce
Rapid determination of branched chain amino acids in human blood plasma by pressure assisted capillary electrophoresis with contactless conductivity detection
Popis výsledku anglicky
A capillary electrophoresis (CE) method with contactless conductivity detection has been developed for the clinical determination of the branched chain amino acids (BCAAs) valine, isoleucine, and leucine in human blood plasma. The CE separation was performed in an optimized background electrolyte with composition 3.2 M acetic acid in 20% v/v methanol, pH 2.0. The achieved separation time was 125 s when using a capillary with an effective length of 14.7 cm, electric field intensity of 0.96 kV/cm and simultaneous application of a hydrodynamic pressure of 50 mbar. The separation efficiency in blood plasma equalled 461 000 theoretical plates/m for valine and isoleucine, and 455 000 theoretical plates/m for leucine; the detection limits are equal to 0.4 ?Mfor all three amino acids. The relative standard deviation values for repeatability of the migration time equalled 0.1% for measurements during a single day and 0.3% for measurements on different days; the relative standard deviation valu
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NT14416" target="_blank" >NT14416: Vliv větvených aminokyselin a saturovaných mastných kyselin na rozvoj inzulínové rezistence</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electrophoresis
ISSN
0173-0835
e-ISSN
—
Svazek periodika
36
Číslo periodika v rámci svazku
16
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
7
Strana od-do
1969-1975
Kód UT WoS článku
000360055300024
EID výsledku v databázi Scopus
—