Biomechanical comparison of a transiliac internal fixator and two iliosacral screws in transforaminal sacral fractures: a finite element analysis
Popis výsledku v původním jazyce
Purpose: Vertically unstable sacral transforaminal fractures can be stabilized with a transiliac internal fixator (TIFI) or two iliosacral screws (IS). This study was designed to compare stiffness between TIFI and IS. Methods: Using CT images finite element model of the pelvis was developed. Denis II type fracture was simulated and fixed either with TIFI or two IS. The sacral base was loaded vertically (250-500 N), displacement magnitudes on medial and lateral fracture surface and the maximum bone stress were calculated. The intact pelvis was used as a reference. Stiffness was determined by linear regression of load and dislocation, computed stiffness ratio %. Von Mises stress was expressed as % ratio, evaluation of colour mapping was made. Results: The mean stiffness ratio medially in TIFI was 75.22 %, in IS 46.54 % (p=0.00005), laterally in TIFI 57.88 %, in IS 44.74 % (p=0.03996). Von Mises stress ratio of TIFI was 139.27 %, of IS 565.35 % (p < 0.00001). Conclusions: Significantly hi
Název v anglickém jazyce
Biomechanical comparison of a transiliac internal fixator and two iliosacral screws in transforaminal sacral fractures: a finite element analysis
Popis výsledku anglicky
Purpose: Vertically unstable sacral transforaminal fractures can be stabilized with a transiliac internal fixator (TIFI) or two iliosacral screws (IS). This study was designed to compare stiffness between TIFI and IS. Methods: Using CT images finite element model of the pelvis was developed. Denis II type fracture was simulated and fixed either with TIFI or two IS. The sacral base was loaded vertically (250-500 N), displacement magnitudes on medial and lateral fracture surface and the maximum bone stress were calculated. The intact pelvis was used as a reference. Stiffness was determined by linear regression of load and dislocation, computed stiffness ratio %. Von Mises stress was expressed as % ratio, evaluation of colour mapping was made. Results: The mean stiffness ratio medially in TIFI was 75.22 %, in IS 46.54 % (p=0.00005), laterally in TIFI 57.88 %, in IS 44.74 % (p=0.03996). Von Mises stress ratio of TIFI was 139.27 %, of IS 565.35 % (p < 0.00001). Conclusions: Significantly hi
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FI - Traumatologie a ortopedie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED1.1.00%2F02.0090" target="_blank" >ED1.1.00/02.0090: NTIS - Nové technologie pro informační společnost</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta of Bioengineering and Biomechanics
ISSN
1509-409X
e-ISSN
—
Svazek periodika
17
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
11
Strana od-do
39-49
Kód UT WoS článku
000354024600005
EID výsledku v databázi Scopus
2-s2.0-84929164388