Determination of glutathione and glutathione disulfide in human whole blood using HPLC with coulometric detection: a comparison with fluorescence detection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11150%2F11%3A10105719" target="_blank" >RIV/00216208:11150/11:10105719 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216275:25310/11:39892024
Výsledek na webu
<a href="http://cccc.uochb.cas.cz/76/4/0277/" target="_blank" >http://cccc.uochb.cas.cz/76/4/0277/</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1135/cccc2010038" target="_blank" >10.1135/cccc2010038</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of glutathione and glutathione disulfide in human whole blood using HPLC with coulometric detection: a comparison with fluorescence detection
Popis výsledku v původním jazyce
We describe a relatively simple method for the determination of glutathione (GSH) and glutathione disulfide (GSSG) in human whole blood. We have used an HPLC with coulometric electrochemical detection for the s?taneous measurement of GSH and GSSG. Diluted and filtered trichloroacetic acid extracts were injected directly into the HPLC system and were eluted isocratically on a Polaris 5u C18-A, 250 x 4.6 mm analytical column. Glutathione in samples extracted with trichloroacetic acid and diluted with 1.0mmol/l hydrochloric acid was stable at 4 oC for at least 8 h. The analytical performance of this method is satisfactory: the intra-assay and inter-assay coefficients of variation were below 10%. Quantitative recoveries from spiked whole blood samples were at intervals 91.6-97.6% for GSH and 85.0-104.4% for GSSG. The linear range is 5.0-2000.0 ?mol/l, with a detection limit of 2.1 ?mol/l (signal-to-noise ratio = 3) for GSH and 2.0-250.0 ?mol/l, with a detection limit of 0.9 ?mol/l for GSS
Název v anglickém jazyce
Determination of glutathione and glutathione disulfide in human whole blood using HPLC with coulometric detection: a comparison with fluorescence detection
Popis výsledku anglicky
We describe a relatively simple method for the determination of glutathione (GSH) and glutathione disulfide (GSSG) in human whole blood. We have used an HPLC with coulometric electrochemical detection for the s?taneous measurement of GSH and GSSG. Diluted and filtered trichloroacetic acid extracts were injected directly into the HPLC system and were eluted isocratically on a Polaris 5u C18-A, 250 x 4.6 mm analytical column. Glutathione in samples extracted with trichloroacetic acid and diluted with 1.0mmol/l hydrochloric acid was stable at 4 oC for at least 8 h. The analytical performance of this method is satisfactory: the intra-assay and inter-assay coefficients of variation were below 10%. Quantitative recoveries from spiked whole blood samples were at intervals 91.6-97.6% for GSH and 85.0-104.4% for GSSG. The linear range is 5.0-2000.0 ?mol/l, with a detection limit of 2.1 ?mol/l (signal-to-noise ratio = 3) for GSH and 2.0-250.0 ?mol/l, with a detection limit of 0.9 ?mol/l for GSS
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Collection of Czechoslovak Chemical Communications
ISSN
0010-0765
e-ISSN
—
Svazek periodika
76
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
18
Strana od-do
277-294
Kód UT WoS článku
000289355200005
EID výsledku v databázi Scopus
—