Percutaneous biopsy of retroperitoneal lesions - 10 year experience of a single centre
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11150%2F20%3A10395734" target="_blank" >RIV/00216208:11150/20:10395734 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00179906:_____/20:10395734 RIV/62690094:18440/20:50017505
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=WVkegu86Es" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=WVkegu86Es</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5507/bp.2019.028" target="_blank" >10.5507/bp.2019.028</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Percutaneous biopsy of retroperitoneal lesions - 10 year experience of a single centre
Popis výsledku v původním jazyce
Aims: To retrospectively evaluate the technical features, efficacy, accuracy, appropriate complications, and relationships among monitored parameters of computed tomography-guided biopsies of the retroperitoneum-located processes. Methods: From December 2008 to December 2018, 208 percutaneous biopsy procedures for tumors, sized 14 - 190 mm in diameter (median size 57.5 mm), were performed on patients with suspected retroperitoneal tumorous process on imaging examinations. The patients were men in 124 cases and women in 84 cases, aged 20 to 90 years (median age 63.2 years). Skin to lesion distance was variable; from 43 cm to 178 cm (median length 108.5 cm). Results: In 202 cases (97.1%) results were true positive or true negative; only 6 interventions (2.9%) were histologically false negative and had to be confirmed surgically. DLBCL and metastatic disease to the retroperitoneal lymphatic nodes were the most common diagnoses (23.1% each); lymphoma types were verified in 40.9% of cases. 7 complications in total were revealed, 6 of which were minor hemorrhages, and in one case ureteral injury was detected. A statistically significant relationship between the hypervascular process and complication incidence (P=0.00166) and needle gauge (P=0.01427) was identified. Conclusion: Percutaneous CT-guided biopsy performed in patients with a suspected retroperitoneal tumorous process had a high accuracy in establishing the correct diagnosis including histological subtyping. Simultaneously, the complication rate was low.
Název v anglickém jazyce
Percutaneous biopsy of retroperitoneal lesions - 10 year experience of a single centre
Popis výsledku anglicky
Aims: To retrospectively evaluate the technical features, efficacy, accuracy, appropriate complications, and relationships among monitored parameters of computed tomography-guided biopsies of the retroperitoneum-located processes. Methods: From December 2008 to December 2018, 208 percutaneous biopsy procedures for tumors, sized 14 - 190 mm in diameter (median size 57.5 mm), were performed on patients with suspected retroperitoneal tumorous process on imaging examinations. The patients were men in 124 cases and women in 84 cases, aged 20 to 90 years (median age 63.2 years). Skin to lesion distance was variable; from 43 cm to 178 cm (median length 108.5 cm). Results: In 202 cases (97.1%) results were true positive or true negative; only 6 interventions (2.9%) were histologically false negative and had to be confirmed surgically. DLBCL and metastatic disease to the retroperitoneal lymphatic nodes were the most common diagnoses (23.1% each); lymphoma types were verified in 40.9% of cases. 7 complications in total were revealed, 6 of which were minor hemorrhages, and in one case ureteral injury was detected. A statistically significant relationship between the hypervascular process and complication incidence (P=0.00166) and needle gauge (P=0.01427) was identified. Conclusion: Percutaneous CT-guided biopsy performed in patients with a suspected retroperitoneal tumorous process had a high accuracy in establishing the correct diagnosis including histological subtyping. Simultaneously, the complication rate was low.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30224 - Radiology, nuclear medicine and medical imaging
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomedical Papers
ISSN
1213-8118
e-ISSN
—
Svazek periodika
164
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
9
Strana od-do
435-443
Kód UT WoS článku
000604951200012
EID výsledku v databázi Scopus
2-s2.0-85097825321