Long-term experience with percutaneous biopsies of pelvic lesions using CT guidance
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11150%2F21%3A10437672" target="_blank" >RIV/00216208:11150/21:10437672 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00179906:_____/21:10437672
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=O8uIlMkgqv" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=O8uIlMkgqv</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1177/00368504211058555" target="_blank" >10.1177/00368504211058555</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Long-term experience with percutaneous biopsies of pelvic lesions using CT guidance
Popis výsledku v původním jazyce
To evaluate the accuracy, efficiency, complication rate, technical features, and relations among followed parameters of CT-guided percutaneous biopsies of the pelvic lesions. 140 biopsies in 136 patients for tumors, sizes 17-160 mm in largest diameter, were carried out in patients with probable tumorous pelvic process within ten years period. The patients were women in 77 cases and men in 59 cases, aged 21 to 87 years. The lesionsÂ' size varied from 17 mm to 160 mm in largest diameter. In 135 biopsies (96.4%) results were true positive or true negative; only 5 procedures (3.6%) were histologically false negative and had to be verified surgically. Metastatic affection was the most common diagnosis (26.4%). Lymphomas were diagnosed in 25%; serous adenocarcinoma of ovary or uterine tube was verified in 15.7% of cases. Totally 7 complications (5%) were confirmed, all were minor hemorrhages. A statistically significant relation between the complication rate and hypervascular character (p =0.00004), and between needle gauge and histological accuracy (p=0.00429) was revealed. Core needle biopsy using percutaneous approach and CT guidance had a high overall accuracy in determining the final histological diagnosis including subtyping. Concurrently, the complication incidence was low.
Název v anglickém jazyce
Long-term experience with percutaneous biopsies of pelvic lesions using CT guidance
Popis výsledku anglicky
To evaluate the accuracy, efficiency, complication rate, technical features, and relations among followed parameters of CT-guided percutaneous biopsies of the pelvic lesions. 140 biopsies in 136 patients for tumors, sizes 17-160 mm in largest diameter, were carried out in patients with probable tumorous pelvic process within ten years period. The patients were women in 77 cases and men in 59 cases, aged 21 to 87 years. The lesionsÂ' size varied from 17 mm to 160 mm in largest diameter. In 135 biopsies (96.4%) results were true positive or true negative; only 5 procedures (3.6%) were histologically false negative and had to be verified surgically. Metastatic affection was the most common diagnosis (26.4%). Lymphomas were diagnosed in 25%; serous adenocarcinoma of ovary or uterine tube was verified in 15.7% of cases. Totally 7 complications (5%) were confirmed, all were minor hemorrhages. A statistically significant relation between the complication rate and hypervascular character (p =0.00004), and between needle gauge and histological accuracy (p=0.00429) was revealed. Core needle biopsy using percutaneous approach and CT guidance had a high overall accuracy in determining the final histological diagnosis including subtyping. Concurrently, the complication incidence was low.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30224 - Radiology, nuclear medicine and medical imaging
Návaznosti výsledku
Projekt
<a href="/cs/project/NT13531" target="_blank" >NT13531: Lidské mezenchymové stromální buňky pro léčebné účely. Preklinické a farmakologické testy a schválení buněčného preparátu pro klinické užití.</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Science Progress
ISSN
0036-8504
e-ISSN
—
Svazek periodika
104
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
14
Strana od-do
00368504211058555
Kód UT WoS článku
000733621600001
EID výsledku v databázi Scopus
2-s2.0-85121758744