Chromatographic determination of active compounds in topical formulations
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F12%3A10124373" target="_blank" >RIV/00216208:11160/12:10124373 - isvavai.cz</a>
Výsledek na webu
<a href="http://pubs.rsc.org/en/content/articlepdf/2011/ay/c1ay05336a" target="_blank" >http://pubs.rsc.org/en/content/articlepdf/2011/ay/c1ay05336a</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1039/c1ay05336a" target="_blank" >10.1039/c1ay05336a</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Chromatographic determination of active compounds in topical formulations
Popis výsledku v původním jazyce
The aim of this study was to develop and validate new methods for the determination of active compounds in topical gels. The method for the determination of nonoxinol-9 and trimecaine hydrochloride in lubricant gel by HPLC with UV detection was described. Separation was carried out using a Discovery ZR-PBD analytical column (150 x 4.6 mm, 5 mu m), and a mobile phase composed of a mixture of triethylammonium acetate buffer (pH 9; 50 mM) and methanol (22 : 78, v/v). Determination of terpinen-4-ol in lubricant gel was achieved by GC with a flame ionization detector (FID). An Alltech-AT-624 (0.32 mm ID x 30 m, 1.8 mu m film thickness) fused-silica capillary column and helium as the carrier gas, at a flow rate of 28 cm s(-1), were employed. The analysis time was less than 7.5 min for HPLC and 5 min for GC analyses. Both methods were successfully applied to the analysis of pharmaceuticals.
Název v anglickém jazyce
Chromatographic determination of active compounds in topical formulations
Popis výsledku anglicky
The aim of this study was to develop and validate new methods for the determination of active compounds in topical gels. The method for the determination of nonoxinol-9 and trimecaine hydrochloride in lubricant gel by HPLC with UV detection was described. Separation was carried out using a Discovery ZR-PBD analytical column (150 x 4.6 mm, 5 mu m), and a mobile phase composed of a mixture of triethylammonium acetate buffer (pH 9; 50 mM) and methanol (22 : 78, v/v). Determination of terpinen-4-ol in lubricant gel was achieved by GC with a flame ionization detector (FID). An Alltech-AT-624 (0.32 mm ID x 30 m, 1.8 mu m film thickness) fused-silica capillary column and helium as the carrier gas, at a flow rate of 28 cm s(-1), were employed. The analysis time was less than 7.5 min for HPLC and 5 min for GC analyses. Both methods were successfully applied to the analysis of pharmaceuticals.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical Methods
ISSN
1759-9660
e-ISSN
—
Svazek periodika
4
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
5
Strana od-do
1525-1529
Kód UT WoS článku
000304768600010