Fast separation of red colorants in beverages using cyano monolithic column in Sequential Injection Chromatography
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F17%3A10364766" target="_blank" >RIV/00216208:11160/17:10364766 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S0026265X16302971" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0026265X16302971</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.microc.2016.10.022" target="_blank" >10.1016/j.microc.2016.10.022</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Fast separation of red colorants in beverages using cyano monolithic column in Sequential Injection Chromatography
Popis výsledku v původním jazyce
Flexible medium-pressure Sequential Injection Chromatography (SIC) flow manifold was used for development of a fast green chromatography method. The article presents novel use of a cyano monolithic column (Merck Chromolith 50 mm x 4.6 mm) for a separation of three water soluble colorants (carmoisine, Ponceau 4R and red 2G), aiming the extension of the SIC separation capabilities for polar analytes. The separation was performed in a gradient elution mode with changing concentration (0.05-0.005% v/v) of ammonium phosphate at pH 6.0 as a mobile phase. No organic modifier was used in mobile phase, thus the green chromatography rules were fulfilled. The vis spectrophotometric detection was set at 500 nm. High performance of the separation with the cyano monolithic column was described and discussed (peak capacities 6.67-10.94, peak symmetries 1.11-1.50, resolutions >= 2.78 and time for one analysis 3.15 min). The method was represented by analytical parameters - LODs of 0.45 mg L-1, a LOQs of 1.5 mg L-1 and calibration range of 1.5-60.0 mg L-1 (r > 0.997) for all analytes, and a method repeatability at 10 mg L-1 of RSD <= 2.69% (n = 5) and system precision of RSD < 1.55% (n = 6). The developed method was used for determination of carmoisine and Ponceau 4R in red coloured beverages with red 2G as an internal standard. The results confirmed benefits of extended chromatographic selectivity of cyano monolithic column in the SIC.
Název v anglickém jazyce
Fast separation of red colorants in beverages using cyano monolithic column in Sequential Injection Chromatography
Popis výsledku anglicky
Flexible medium-pressure Sequential Injection Chromatography (SIC) flow manifold was used for development of a fast green chromatography method. The article presents novel use of a cyano monolithic column (Merck Chromolith 50 mm x 4.6 mm) for a separation of three water soluble colorants (carmoisine, Ponceau 4R and red 2G), aiming the extension of the SIC separation capabilities for polar analytes. The separation was performed in a gradient elution mode with changing concentration (0.05-0.005% v/v) of ammonium phosphate at pH 6.0 as a mobile phase. No organic modifier was used in mobile phase, thus the green chromatography rules were fulfilled. The vis spectrophotometric detection was set at 500 nm. High performance of the separation with the cyano monolithic column was described and discussed (peak capacities 6.67-10.94, peak symmetries 1.11-1.50, resolutions >= 2.78 and time for one analysis 3.15 min). The method was represented by analytical parameters - LODs of 0.45 mg L-1, a LOQs of 1.5 mg L-1 and calibration range of 1.5-60.0 mg L-1 (r > 0.997) for all analytes, and a method repeatability at 10 mg L-1 of RSD <= 2.69% (n = 5) and system precision of RSD < 1.55% (n = 6). The developed method was used for determination of carmoisine and Ponceau 4R in red coloured beverages with red 2G as an internal standard. The results confirmed benefits of extended chromatographic selectivity of cyano monolithic column in the SIC.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30104 - Pharmacology and pharmacy
Návaznosti výsledku
Projekt
<a href="/cs/project/GA15-10781S" target="_blank" >GA15-10781S: On-line spojení automatizovaných extrakčních procesů s kapalinovou chromatografií pro kompletní analýzu vzorku</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Microchemical Journal
ISSN
0026-265X
e-ISSN
—
Svazek periodika
130
Číslo periodika v rámci svazku
January
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
384-389
Kód UT WoS článku
000390072400054
EID výsledku v databázi Scopus
2-s2.0-84994017856