Voltammetric determination of selected nitro compounds at a polished silver solid amalgam composite electrode.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F11%3A10105001" target="_blank" >RIV/00216208:11310/11:10105001 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388955:_____/11:00358309
Výsledek na webu
<a href="http://dx.doi.org/10.1002/elan.201000428" target="_blank" >http://dx.doi.org/10.1002/elan.201000428</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.201000428" target="_blank" >10.1002/elan.201000428</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Voltammetric determination of selected nitro compounds at a polished silver solid amalgam composite electrode.
Popis výsledku v původním jazyce
Voltammetric behavior of selected biologically active organic nitro compounds, namely 2-nitrofluorene, picric acid (2,4,6-trinitrophenol) and metronidazole, has been investigated using direct current voltammetry (DCV) and differential pulse voltammetry (DPV) at a polished silver solid amalgam composite electrode (p-AgSA-CE). The optimum conditions have been found for their determination in a 1:1 mixture of methanol and aqueous Britton-Robinson buffer of pH 5.0 for 2-nitrofluorene and in the aqueous Britton-Robinson buffer solutions of pH 2.0 and 4.0 for picric acid and metronidazole, respectively, with the limits of quantification (L(Q)s) 4, 0.1 and 2 mu molL(-1) (DCV at p-AgSA-CE) and 3, 1 and 4 mu molL(-1) (DPV at p-AgSA-CE) for 2-nitrofluorene, picric acid and metronidazole, respectively. An attempt to increase the sensitivity using adsorptive stripping voltammetry was not successful for all three test substances. For comparison, the UV-vis spectrophotometric determinations of studi
Název v anglickém jazyce
Voltammetric determination of selected nitro compounds at a polished silver solid amalgam composite electrode.
Popis výsledku anglicky
Voltammetric behavior of selected biologically active organic nitro compounds, namely 2-nitrofluorene, picric acid (2,4,6-trinitrophenol) and metronidazole, has been investigated using direct current voltammetry (DCV) and differential pulse voltammetry (DPV) at a polished silver solid amalgam composite electrode (p-AgSA-CE). The optimum conditions have been found for their determination in a 1:1 mixture of methanol and aqueous Britton-Robinson buffer of pH 5.0 for 2-nitrofluorene and in the aqueous Britton-Robinson buffer solutions of pH 2.0 and 4.0 for picric acid and metronidazole, respectively, with the limits of quantification (L(Q)s) 4, 0.1 and 2 mu molL(-1) (DCV at p-AgSA-CE) and 3, 1 and 4 mu molL(-1) (DPV at p-AgSA-CE) for 2-nitrofluorene, picric acid and metronidazole, respectively. An attempt to increase the sensitivity using adsorptive stripping voltammetry was not successful for all three test substances. For comparison, the UV-vis spectrophotometric determinations of studi
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CF - Fyzikální chemie a teoretická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
23
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
10
Strana od-do
129-139
Kód UT WoS článku
000285889900016
EID výsledku v databázi Scopus
—