Determination of 1-hydroxypyrene in human urine by HPLC with electrochemical detection at a boron-doped diamond film electrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F12%3A10126406" target="_blank" >RIV/00216208:11310/12:10126406 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s00216-012-6140-2" target="_blank" >http://dx.doi.org/10.1007/s00216-012-6140-2</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00216-012-6140-2" target="_blank" >10.1007/s00216-012-6140-2</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of 1-hydroxypyrene in human urine by HPLC with electrochemical detection at a boron-doped diamond film electrode
Popis výsledku v původním jazyce
A high-performance liquid chromatographic method with electrochemical detection (HPLC-ED) at a boron-doped diamond film electrode with preliminary separation and preconcentration by solid-phase extraction (SPE) has been developed for the determination of1-hydroxypyrene (1-HP) in human urine. 1-HP is among the most widely used biomarkers of exposure to polycyclic aromatic hydrocarbons. Optimal HPLC-ED conditions have been found: mobile phase methanol-0.05 mol L-1 phosphate buffer pH 5.0 (80:20, v/v), detection potential +1,000 mV versus Ag/AgCl (3 mol L-1 KCl), and flow rate 0.8 mL min(-1). For SPE, LiChrolut(A (R)) RP-18 E cartridges were used. The extraction yield was (87.0 A +/- 5.8) % (n = 5). The concentration dependence of 1-HP was measured in the concentration range from 0.01 to 10 mu mol L-1 (2.18-2,180 mu g L-1) using methanolic solutions resulting from the SPE pretreatment of spiked human urine samples. The limit of detection (signal-to-noise ratio 3) and the limit of quantif
Název v anglickém jazyce
Determination of 1-hydroxypyrene in human urine by HPLC with electrochemical detection at a boron-doped diamond film electrode
Popis výsledku anglicky
A high-performance liquid chromatographic method with electrochemical detection (HPLC-ED) at a boron-doped diamond film electrode with preliminary separation and preconcentration by solid-phase extraction (SPE) has been developed for the determination of1-hydroxypyrene (1-HP) in human urine. 1-HP is among the most widely used biomarkers of exposure to polycyclic aromatic hydrocarbons. Optimal HPLC-ED conditions have been found: mobile phase methanol-0.05 mol L-1 phosphate buffer pH 5.0 (80:20, v/v), detection potential +1,000 mV versus Ag/AgCl (3 mol L-1 KCl), and flow rate 0.8 mL min(-1). For SPE, LiChrolut(A (R)) RP-18 E cartridges were used. The extraction yield was (87.0 A +/- 5.8) % (n = 5). The concentration dependence of 1-HP was measured in the concentration range from 0.01 to 10 mu mol L-1 (2.18-2,180 mu g L-1) using methanolic solutions resulting from the SPE pretreatment of spiked human urine samples. The limit of detection (signal-to-noise ratio 3) and the limit of quantif
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical and Bioanalytical Chemistry
ISSN
1618-2642
e-ISSN
—
Svazek periodika
404
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
7
Strana od-do
693-699
Kód UT WoS článku
000307251900011
EID výsledku v databázi Scopus
—